102
7.1.3
Testing the Quantity of Ground Coffee and Water
You can use the
Test
key at any time during setting to run a
test brewing cycle (trial) to check the result of the changes
you have made to the settings. You can choose whether to
test the freshly prepared coffee beverage (“Fresh”) or, on
machines with a storage reservoir, the quantity of beverage
portioned from the storage reservoir.
If you choose to test the freshly prepared coffee beverage,
you have a choice of 3 options:
x
“Beverage”
: a brewing cycle using ground coffee
from the ground coffee hopper is carried out in
accordance with your settings.
x
“Ground coffee”
: the brewer travels upwards and
you can open the front door and hold a suitable
measuring cup (for example, a coffee cup) over the
brewing chamber. On pressing the Start key in the
display, your set quantity of ground coffee will be
dispensed into your measuring cup.
Caution! Injury hazard!
Beware of the risk of injury while ground coffee
dispensing is taking place. Never place your hand
in the hopper outlet area.
Press
to accept the new settings or press
to quit the
Settings menu without applying the changes.
To allocate the selected beverage key to a different
beverage, scroll to page 2 of the Settings menu. Select the
beverage key (in this case, “Beverage Cup”) then use the
or
key to choose another standard beverage or
to disable the key if desired.