82
User Manual WMF cafemat!
Appendix: Technical data
Mains
voltage tolerance
range
230 V + 6 % - 10 %, mains voltage interruption < 50 ms,
no interruption of function
Water supply
3/8 inch flexihose connector with mains tap and filter on
customer supply side, water temperature max. 35 °C.
Min. 0.2 MPa flow pressure at 2 l/min., max. 0.6 MPa.
Use the hose supplied with the new coffee machine and/or new
water filter. Do not use old hoses.
Water quality
For drinking water with a carbonate hardness above 9 ° dkH,
a WMF scale filter should be installed upstream.
Water drain pipe
(optional)
Hose, min. DN 19, minimum downward slope of 2 cm/m
Ambient temperature + 5 °C to max. of + 35 °C
(empty the water line in case of frost)
Protection
80 % relative humidity without condensation.
No water spray. Do not use unit outdoors.
Do not use steam jets or steam cleaners or the like. Do not steam
the unit.
Protrction
IP X0
Installation surface
The unit must be placed on a level, sturdy surface.
Inbuilt clearances
For operating, service, and safety reasons the machine should
be installed with a clearance of not less than 50 mm at the back
and sides from the building or non-WMF components. A clear
height of 100 mm from the top of the supporting surface should
be ensured. The height of the installation surface above the
floor is at least 850 mm. If the machine connections are to be
run downwards through the counter, please make space for the
lines, which can reduce the usable space below the machine.
Installation dimensions
of the scale filter
See filter manual.