Maintenance concept
28
Service maintenance 2
33 2893 9000
Module
No.
Designation
Order number
Count
Illustration (not to scale)
Brewer
1
Brewing piston, compl.
33 2897 2000
2
Coffee / hydraulics
2
Brewing valve socket
33 2400 8000
2
Ventilation / cooling
3
Fan
33 2617 5000
2
Coffee / hydraulics
4
Release valve socket
33 2274 5000
2
Steam / hydraulics
5
Socket for linked valves
(without union nuts)
33 2894 9000
1
Steam / hydraulics
6
Socket for steam barrier valve
33 2273 9000
1
Hot water / hydraulics
7
Socket for hot water mixing valve
33 2273 9000
1
Hot water / hydraulics
8
O-Ring water filter
33 2283 2000
1
Hot water / hydraulics
9
Water filter sieve
33 1509 2000
1
Coffee / hydraulics
10
NTC cold water mix-in O-ring
33 2534 8000
2
Hot water / hydraulics
11
Reducer, water filter
33 2354 1000
1
Note for technicians:
Service maintenance 2 coincides with descaling of the steam boiler. During the descaling of the steam boiler, the water filter sieve must be removed from the
water filter (risk of blockage due to suspended particles). The new water filter sieve must only be used AFTER descaling (otherwise there is a risk that descaler resi-
dues may get into the water filter).
Service maintenance 2 coincides at the same time as the boiler pressure test.