17
Conveyor Belt Replacement
To replace the conveyor belt:
1. Disconnect the machine from the power
source. Unplug the motor cord from the
control box.
2. Raise the drum to its highest position using
the handwheel (Fig. 16, Item A).
3. Remove the belt tension by loosening the
take-up nuts (Fig. 16, Item B).
4. Unscrew the four socket head cap screws
(Fig. 16, Item C) that attach the conveyor to
the bed and remove the conveyor.
5. Slide the conveyor belt off the conveyor and
replace it with a new belt.
Tension Roller Alignment
1. Remove the abrasive strip (Fig. 17, Item D)
from the drum.
2. Loosen all four bearing hex nuts (Fig. 17,
Item E).
3. This will allow the tension rollers to drop to
the lowest position.
4. Lower the sanding drum so that it just
touches the conveyor bed.
5. Turn the drum height handle one complete
revolution to raise the drum.
6. Retighten the bearing hex nuts.
Tension Roller Pressure Adjustment
You can also adjust the spring-loaded screws
found on the pressure roller brackets, to
increase or decrease roller pressure. If you are
getting snipe marks at the leading end of the
board adjust the outfeed roller pressure. If the
snipe marks occur on the trailing end of the
board, adjust the infeed roller pressure.
Drum Height Control Adjustment
If the height control mechanism does not
operate easily or smoothly, or there is excessive
vertical movement or deflection of the drum
carriage, perform the following adjustments.
1. Tighten all four lock nuts (Fig. 18, Item F)
and then loosen them 1/8 to 1/4 turn.
2. Thoroughly lubricate the mating surfaces
and the height adjustment screw.
Summary of Contents for PERFORMAX 22-44 Plus
Page 19: ...19 Drum Head Assembly...
Page 22: ...22 Conveyor and Motor Assembly...
Page 24: ...24 Wiring Diagram...