4-10
Chapter 4: Troubleshooting
November 2007
Hopper Diagnostics
Complete the following steps to test the Hopper:
1
From the
Administration Menu
, select
Diagnostics.
2
Select
Input/Output Diagnostics
.
3
Select
Cash Devices Diagnostics
.
4
Select
Hopper
.
The
Hopper Diagnostic
screen displays,
.
Figure 4-9 Hopper Diagnostics screen.
5
Perform a 1-Coin test:
a
Select
Paid 1 Coin
.
b
The Hopper dispenses a single coin.
c
The
Coin Paid
counter increments to
1
.
6
Perform a 10-Coin test:
a
Select
Paid 10 Coins
.
b
The Hopper dispenses 10 coins.
c
The
Coin Paid
counter increments to
10
.
7
If necessary, select
Hopper Shutoff
to stop the Hopper from dispensing coins.
8
When the test is complete, select
Exit
.
9
Under special circumstances, such as when the Main Door is closed as the test is completing,
an
Exit
banner displays for 2.5 seconds.
Summary of Contents for Bluebird Series
Page 2: ......
Page 12: ...4 List of Figures November 2007 ...
Page 16: ...4 About this Guide General Information October 2007 ...
Page 101: ...5 13 Chapter 5 Exploded Views Block Diagram for BBU AC Power Distribution ...
Page 102: ...5 14 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 103: ...5 15 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 104: ......