Tilt Codes
16-020834-00
EPROM System
Error
Critical error: An invalid signature
ID was detected and all processes
were suspended.
Perform the corresponding solution:
RAM Clear
Replace the CPU Board battery and RAM Clear.
Extra Coin Out
The OS detected a coin out after
the payout was complete.
Check Hopper and knife.
Hard Meter 1
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 2
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 3
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 4
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 5
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 6
disconnected
The meter connector is
disconnected.
Check the meter connection. If necessary,
replace the meter harness.
Replace the CPU Board.
Replace Bulkhead.
Hard Meter 1
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hard Meter 2
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hard Meter 3
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hard Meter 4
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hard Meter 5
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hard Meter 6
shorted
The meter connector is shorted.
Check the meter connection. If necessary, replace
the meter harness.
Hood Door Open
Hatch Door is open. (Slant ONLY)
Check the Hatch Door.
Check connections on cherry switch.
Replace switch.
Replace the CPU Board.
Replace Bulkhead.
Hopper Device
Error
The OS detected that the time
between coin-out pulses was too
short.
Perform a Hopper Test.
Hopper Empty
The OS detected that no coins
were dispensed after a time out
period.
Check or fill Hopper.
Hopper Jam
For the Gamesman, a jam
condition is established if the
motor stops during a payout.
Check the Hopper and clear any jams or debris from
Hopper.
Hopper Runaway
The OS detected multiple coins
out after the payout was complete.
Check Hopper electronics.
Hopper System
Error
The OS detected an error not
covered in the other error types.
Check the Hopper connection to the Bulkhead Board.
Table 4-4 Tilt Codes (continued).
Display
Definition
Possible Solution(s)
Summary of Contents for Bluebird Series
Page 2: ......
Page 12: ...4 List of Figures November 2007 ...
Page 16: ...4 About this Guide General Information October 2007 ...
Page 101: ...5 13 Chapter 5 Exploded Views Block Diagram for BBU AC Power Distribution ...
Page 102: ...5 14 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 103: ...5 15 Chapter 5 Exploded Views Block Diagram for BBU Bulkhead with CPU NXT ...
Page 104: ......