background image

 

www.wobit.com.pl 

User Manual  - SMC124– 15.07.2015 – v.1.2 

   Page 5 

 

 

Exemplary values of current efficiencies of used power supply: 

                       Motor current [A] 
Power supply [V] 

12 

1A 

2A 

3A 

24 

0,5A 

1A 

2A 

36 

0,4A 

0,8A 

1,5A 

 

 

CAUTION!  

Reverse polarity or exceeding maximal voltage supply can cause damage of the driver. 

 

During  operation  with  high  voltage  supply  and  large  motor  which  operates  dynamically  (rapid 
decreasing of its velocity), too small output capacitors or lack of them can damage the driver or 
cause its incorrect operation. 

 

 

2.4

 

Connection of the driver 

Motor should be connect to the driver using 4-wire cable. To minimize noises it is recommended to 
use twisted pair cable (A with /A, B with /B), for the best shielded. In case of unipolar motors (with 6 
or 8 derivations) connection can be made serial or parallel.  

 

 

Connection of 4 –wire motor 

Example of connection of bipolar stepper motor  

 

Serial connection of 8(6)-wires motor  

 

Coiling  connected  serially  to  achieve  higher  maximal  torque 
of the motor decreasing of its dynamics.  

 

 

Parallel connection of 8-wires motor 

 

Coiling connected parallels to achieve higher maximal motor 
velocity and better operational dynamics  

Increased 

maximal  current/phase  in  relation  to  rated  current 

x1,4

 (for example motor with current 2A, can be operated with 

max. current 2,8A). 

 

 

CAUTION!  

Do not disconnect motor from the driver during its operation. It can cause damage of the driver.

 

 

2.5

 

Controlling inputs 

All controlling inputs (CLK, DIR, ENABLE) are opt insulated. It operates with 5V (high state 3..6V). To 
control  from  voltage  level  24  V  into  a  row  with  controlling  signals  insert  resistors  with  value  
1,5..2,2k. 
 
Controlling signals should be connected according to scheme below:  

 

Summary of Contents for SMC124

Page 1: ...H WObit E K J Ober s c 62 045 Pniewy D borzyce 16 tel 61 22 27 422 fax 61 22 27 439 e mail wobit wobit com pl www wobit com pl SMC124 User Manual Stepper motor driver 0 5 3 6 A Step resolution 1 2 1...

Page 2: ...t correct service and accurate exploitation of described device Information included in this instruction were prepared with high attention by our specialists and is description of the product Based on...

Page 3: ...r should be shielded or twisted in pairs separate twisted pair for A and B phase It is also recommended to use a ferrite ring on motor cable at controller 2 Signal cables CLK DIR EN should be move awa...

Page 4: ...ectors and signalizing indicators Picture 1 Description of connectors and indicators of SMC124 driver No Description Inputs POWER Power supply input 12 36 VDC MOTOR Output for connection of stepper mo...

Page 5: ...r 8 derivations connection can be made serial or parallel Connection of 4 wire motor Example of connection of bipolar stepper motor Serial connection of 8 6 wires motor Coiling connected serially to a...

Page 6: ...FF ON OFF 1 20 ON ON ON 1 32 ON ON OFF 1 64 OFF OFF OFF ON 1 128 ON OFF ON Current I1 I2 I3 I4 0 5 OFF OFF OFF OFF 1 2 ON OFF OFF OFF 1 6 OFF ON OFF OFF 2 0 ON ON OFF OFF 2 5 OFF OFF ON OFF 2 7 ON OFF...

Page 7: ...meters Description Parameter Power supply 12 36 VDC Motor phase current 0 5 3 6A Step resolution 1 2 1 8 1 10 1 16 1 20 1 32 1 64 1 128 Controlling signals CLK DIR EN Low state 2V high state 5V CLK co...

Reviews: