Manual_S5_Airplus_2015_04_20
Page 18 / 68
©
Wodtke GmbH - Tübingen. All Rights and Changes Reserved.Printed 04/2015
Part No. 950 976
7
Placement of the Furnace
Please observe the specifications on fire protec-
tion regulations in Chapter 10.
The furnace must be installed on a sufficiently
load-bearing and non-flammable base. At least 20
cm of free space must be available to the rear and
sides of the furnace after installation for assembly
work.
Adjust the feet of the furnace to 25 mm floor clear-
ance to the bottom edge of the panelling at the in-
stallation location so that sufficient convection air
can flow in from below / laterally below (see Fig.
2).
8
Electrical Connection / Ca-
bling
The power plug must be disconnected before
performing electrical work on the unit!
Electrical connections on the unit must be made
by a qualified specialist in accordance with appli-
cable local technical rules, particularly the VDE
guidelines. No liability is accepted for damage to
the unit due to improper connections, and any war-
ranty is void.
No electrical connection cables from and to the
unit may contact hot exterior surfaces of the fur-
nace or of the flue pipe. The installation may not
be made over sharp edges, corners, etc. All elec-
trical connections are located on the main board
of the furnace.
The rear bottom panel and the left side panel or
the front bottom panel of the furnace may have to
be removed for the electrical connection, depend-
ing on the desired connection (for removal of outer
panelling, see Chapter 6). The connection lines
can be installed from below through the floor (hid-
den installation) or above the floor (see diagram
below).
The guard covering over the main board may not
be removed for the external electrical connection
(this covering protects the main board from soot
and dirt and is only removed when replacing com-
ponents)! The furnace may only be operated with
this cover in place!
Fig. 28: connection diagram