Page
10
Figure 2-2: Display Features
1.
Input Status
: Displays the selected input and video parameters of vertical
active line count, (i)nterlaced or (p)rogressive, and field/frame rate in Hz.
This display may be active for a few seconds after a source is selected, or it
can be displayed all of the time. This selection is made in the SETTINGS
menu.
2.
Ratio Marker
: Used to mark an alternate aspect ratio area of the image.
You can set whether to display it in the DISPLAY menu.
3.
Safe Zone Marker
:
This is used to mark a percentage area, inside of the
image, safe for titles to be located. You can set whether to display it in the
DISPLAY menu.
4.
Center Marker
:
Cross hairs
are
displayed in the center of the screen,
marking the center of the image. You can set whether to display it in the
DISPLAY menu.
5.
IMD
:
The OSD MENU provides settings to customize the IMD (In Monitor
Display) text area to show a static line of characters, numbers, and some
symbols or to receive dynamic messages to display. This can be set in the
TOOLS menu.
6.
Audio Level Meters
:
Levels for the audio channels are displayed on up to
sixteen meters as left/right pairs. Up to sixteen meters can appear in the
lower left corner of the screen. This can be adjusted in the AUDIO menu.
7.
Waveform/Vectorscope/Histogram
:
This can be displayed only for an
SDI signal. These input signal displays are configurable in the SIGNAL Menu.