background image

2

© 2007

Wohler Technologies, Inc.

   ALL rights reserved

Introduction

Congratulations on your selection of a PANORAMAdtv product. We are confident it represents the best performance and value
available, and we guarantee your satisfaction with it.

If you have questions or comments you may contact us at:

Wohler Technologies, Inc.

31055 Huntwood Avenue

Hayward, CA  94544

Phone:

(510) 870-0810

     Fax: 

(510)  870-0811

US Toll-Free: 

1-888-596-4537

www.panoramadtv.com

sales@panoramadtv.com

1)

Read these instructions.

2)

Keep these instructions.

3)

Heed all warnings.

4)

Follow all instructions.

5)    Do not use this apparatus near water.

6)    Clean only with dry cloth.

7)    Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.

8)       Do not install near any heat source such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9)      Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two blades

with one wider than the other.  A grounding type plug has two blades and a third grounding prong.  The
wide blade or the third prong are provided for your safety.  If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.

10)   Protect the power cord from being walked on or pinched, particularly at plugs convenience receptacles

and the point where they exit from the apparatus.

11)   Only use attachments/accessories specified by the manufacturer.

12)  Use only with the cart stand, tripod, bracket, or table specified by the manufacturer, or sold with the

apparatus.  When a cart is used, use caution when moving the cart/apparatus combination to avoid injury
from tip-over.

13)   Unplug this apparatus during lightning storms or when unused for long periods of time.

14)  Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been

damaged in any way, such as when power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.

15)  Do not expose this apparatus to rain or moisture.

16)  The apparatus shall be connected to a mains socket outlet with a protective earthing connection.

Important Safety Instructions

CAUTION!

In products featuring an audio amplifier and speakers, the surface at the side of the
unit, where the audio amplifier heat sink is internally attached, may get very hot after
extended operation.  When operating the unit excercise caution when touching this
surface and ensure that external materials which may be adversely affected by heat
are not in contact with it. There is a Hot Surface label (see diagram) attached to the
aforementioned surface of the product.

Summary of Contents for RM-3358W

Page 1: ...eenDiaplyControlsOperation RearPanelFeatures Section 3 Technical Information TallyControlConnectorWiring RM 3358W Document P N 821575 Rev C 3U Triple LCD Video Monitor with Three 5 8 16 9 LCD Video Di...

Page 2: ...ing walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only wi...

Page 3: ...3 2006 PANORAMAdtv ALL rights reserved RM 3358W User Manual P N 821575 Rev C General Features and Specifications Description Features Applications Specifications Options Section 1...

Page 4: ...ay also features a tri color red green yellow tally LED indicator A DB25 connector on the rear panel is used to interface the RM 3358W with your facilities tally system An optional field installable a...

Page 5: ...pe top 30 degrees bottom 60 degrees left 60 degrees right 60 degrees 150 typical 400 NITs cd m 2 10 000 hours minimum 15 000 hours average 30 watt typical 48 watt max 110 220 VAC 12VDC external power...

Page 6: ...ture inside the mounting enclosure does not exceed 40 degrees Celsius 104 degrees Fahrenheit adjacent devices can be rack mounted or stacked in proximity to the RM 3358W unit If the above temperature...

Page 7: ...7 2006 PANORAMAdtv ALL rights reserved RM 3358W User Manual P N 821575 Rev C Operation Front Panel Features On Screen Display Controls Operation Rear Panel Features Section 2...

Page 8: ...Saturation adjust for desired amount of image color saturation Tint Hue adjust for desired image color hue NTSC only Dimmer Level 1 to 8 Power Savings ON OFF turns monitor off if no video signal afte...

Page 9: ...reserved RM 3358W User Manual P N 821575 Rev C 2 3 5 1 4 VIDEO B VIDEO B 1 VIDEO A POWER DOWN UP MENU POWER 2 VIDEO A UP DOWN MENU POWER 3 VIDEO A MENU UP VIDEO B DOWN RM 3358W Section 2 Operation Fi...

Page 10: ...n 2 Press the UP and DOWN buttons to scroll through the options 3 Press the MENU button to select the chosen parameter for adjustment 4 Press the UP and DOWN buttons to adjust the level 5 Press the ME...

Page 11: ...Hz 1 Press MENU button to select FSC SET 3 5MHz Frequency Subcarrier option 2 Press UP and DOWN buttons to select FSC SET 3 58MHz or FSC SET 4 43MHz 3 Press MENU button to activate selection This opti...

Page 12: ...e supplied at these BNC connectors If you supply downstream equipment from these connectors ensure that you set the appropriate Termination Switch Item A according to your configuration Note that if a...

Page 13: ...13 2006 PANORAMAdtv ALL rights reserved RM 3358W User Manual P N 821575 Rev C Figure 2b Rear Panel Features Section 2 Operation...

Page 14: ...C 17 639 448 03 mm Internal Rack Clearence Stnd Conn Clearence RMSDI Option Connector Clearence 4 454 113 13 mm 7 913 200 99 mm 18 876 479 45 mm Figure 2c RM 3358W Top View Depth and Width Clearance...

Page 15: ...dschematicsupportdocumentationisavailableuponrequest PANORAMAdtv 31055 HuntwoodAvenue Hayward CA 94544 1 888 596 4537 Fax 510 870 0811 web www panoramadtv com e mail sales panoramadtv com Wohler Techn...

Page 16: ...mer provided power supply and tally system If your facility currently has a tally system with companion power source use this method to integrate the RM Monitor tallies with your existing tally matrix...

Page 17: ...17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13 DB25 MALE RED GRN USER CABLE CONNECTOR IS MALE OPEN COLLECTOR RED GRN CHOOSE LED BY JUMPING R RED OR G GREEN TO C R G C NPN RED GRN R G C NPN NPN RED G...

Page 18: ...1055 HuntwoodAvenue Hayward CA 94544 1 888 596 4537 Fax 510 870 0811 web www panoramadtv com e mail sales panoramadtv com Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510 870 0...

Reviews: