Page
20
DISPLAY
MODE
MODE1
MODE1: meters only
MODE2: meters with
channel numbers and
frame
Select the appearance
of the meters.
METER
OPACITY
0
0 = 100%
1 = 50%
Set the opacity of the
audio meters.
Menu Page 3
MARKER
OFF
OFF, ON
Enable or disable the
display of the markers
that have been set up
in this menu.
ASPECT
MARKER
OFF
16:9
4:3
15:9
14:9
13:9
1.85:1
2.35:1
Variable
Off
Select the aspect
marker according to the
display aspect ratio.
VARIABLE
ASPECT
3.00
1.00 - 3.00 in 0.01
steps
When the Aspect
Marker is set to
Variable, use this ratio.
CENTER
MARKER
OFF
OFF, ON
Turn center marker
display on or off.
SAFE AREA
MARKER
OFF
OFF
80%
85%
88%
90%
93%
95%
Set safety marker size
according to the aspect
ratio and scan mode.
MARKER FIT
OFF
OFF: Safe Area Marker
is based upon the
current input source
ON: Safe Area Marker
is based upon the
image within the
current aspect
Select Safe Area Marker
setup.
MARKER
LEVEL
1
1: 50%
2: 75%
3: 100%
Set the luminance of all
of the markers.
MARKER MAT OFF
OFF,
HALF (
Background
50%)
BLACK
(Refer to Figure 2-7)
Set the transparency of
the area marker mat.
CROSSHATCH ON
OFF, ON
Set whether to show
the crosshatch.