Operating the Wöhler BC 600 via the app
48
8.6.1 Leakage test without
app
It is possible to carry out a leakage test without
the app. However, in that case it is not possible to
save the measurement values.
NOTE!
To carry out leak detection without an app, the
Wöhler BC 600 must not be connected to a WLAN
client, otherwise the buttons are deactivated.
•
When the device ist powered on, press the
Start/Stop key to start the leakage test and
then subsequently to stop the test.
The leakage test will then be carried out at a neg-
ative pressure of 50 Pa. It is possible to alter this
value under Settings in the app, see chapter 9. In
this case the new value is stored in the device for
measurement without the app.