*Downdraft systems are not recommended for use with these models.
CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu
(.03 kW)
. Additional CFM may be required for long duct runs or
ranges and rangetops with a charbroiler or griddle.
Ventilation Made Easy
10
Step 2: Determine the CFM
The chart below provides CFM specific to the cooking
appliance and ventilation system used. CFM are based on
the cooking appliance output. Wolf suggests 1 CFM per
100 Btu
(.03 kW)
. Additional CFM may be required for long
duct runs and ranges or rangetops with a charbroiler or
griddle.
IMPORTANT NOTE:
Specifing a blower with less CFM than
listed in the chart below will result in decreased airflow
and performance.
When determining the proper CFM for your installation,
take into consideration the equivalent duct length calcu-
lated on the previous page.
IMPORTANT NOTE:
Consult a qualified HVAC professional
for specific applications.
WOLF PRODUCT CFM
COOKTOP HOODS
DOWNDRAFTS
PRO HOODS
MODEL
CFM
CFM
CFM
COOKTOPS AND MODULES
CT15I CT15E CT15G IG15* IS15* IF15* IM15
215
150
215
CT30I CT30IU* CT30E CT30EU* CT30G
450
350
500
CT36I CT36IU* CT36E CT36EU* CT36G
600
500
500
DUAL FUEL RANGES
DF304
500
DF366 DF364C DF364G
900
DF486C DF486G DF484CG DF484DG DF484F
1100
DF606DG DF606F DF606CG DF604CF DF604GF
1500
SEALED BURNER RANGETOPS
SRT304
500
500
SRT366
500
900
SRT364C SRT364G
900
SRT486C SRT486G SRT484CG SRT484DG SRT484F
900
GAS RANGES
R304
500
R366 R364C R364G
900
R488 R486C R486G R484CG R484DG R484F
1100
R606DG R606F R606CG
1500
GAS RANGETOPS
RT366 RT364C RT364G RT362F
900
RT488 RT486C RT486G RT484CG RT484DG RT484F
1100