15. Roof integration, high roof tiles
(convex - concave tiles)
For safety reasons, the [German] roofing contractor's association specifies a covered
substrate with bitumen sheeting, reinforced foil or other suitable material below the
collector area to prevent the ingress of moisture into the building in case of leaks. This
sub-roof must terminate in the roof gutter.
Standard dimensions for
determining the position of
the collector array
Min. 3.0
m
Align
Width with flashing pieces /
lift plates
Collector array width
Collector array width
Width with cover frame
Top cover panels
Top mounting rail
Bottom mounting rail
Flashing tape
base, L.h.
Flashing tape
Triangular sealing tape
Edge
protector
Timber spacer of 15 to 30 mm
height to match to the battens
Screws, nuts, grub screws,
woodscrews in a bag
Intermediate
panels
Connecting rail
Flashing tape base, R.h.
Right hand
cover panel
Left hand
cover panel
Standard delivery
Installation parts
Number of collectors
2
3
4
5
6
7
8
9
10 *)
Width of the collector array [m]
2.36
3.49
4.62
5.75
6.88
8.01
9.14
10.27
11.40
Width with cover frame [m]
2.73
3.86
4.99
6.12
7.25
8.38
9.51
10.64
11.77
NB