22
|
Wolf Customer Care 800.222.7820
VENTILA
TION
OUTDOOR GRILLS
RANGES / RANGETOPS
COOKTOPS / COFFEE
BUIL
T-IN OVENS
GAS REQUIREMENTS
NATURAL GAS
WC
Supply Pressure
5"
(12.5 mb)
Min Line Pressure
7"
(17.5 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
LP GAS
WC
Supply Pressure
10"
(25 mb)
Min Line Pressure
11"
(27.4 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
Planning Information
GAS SUPPLY
Installation must conform with all applicable gas codes.
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided
to the gas multifunction cooktop. If local codes permit, a
certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal
appliance connector is recommended to connect the units
1
/
2
" NPT male inlet to the gas supply line.
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas cooktops
will function up to 8,600'
(2621 m)
. If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
INTEGRATED MODULES