Flue gas damper connection (230 V; max.200 VA)
Insert the cable glands into the terminal box. Insert
and secure the connecting cable through the cable
gland. Connect the connecting cable to terminals L1, N,
and .
Fig.: Flue gas damper connection
Changing a fuse
Isolate the boiler from the main supply prior
to changing a fuse. The ON/OFF switch on
the boiler does not provide separation from
the power supply.
Danger through 'live' electrical components.
Never touch electrical components or
contacts if the boiler has not been isolated
from the power supply. Danger of death.
Fig.: Pivot the control unit forward, terminal box
cover open
Fuse
Electrical connection CGU-2(K)
Connection to
Output A1 (230 VAC; max.200 VA)
Insert the cable glands into the terminal box. Insert
and secure the connecting cable through the cable
gland. Connect the connecting cable to terminals L1,
N and .
Fig.: Connection output A1
Installation information, electrical connection
- Isolate the system from the power supply before
opening the casing.
- Pivot the control unit to the side.
- Open the terminal box.
- Insert the strain relief into the holes provided.
- Strip approx. 70 mm off the power supply cable
insulation.
- Push the cable through the strain relief and
secure the strain relief.
- Pull the Rast-5 plug.
- Terminate the appropriate cores at the Rast-5 plug.
- Push the inserts back into the terminal box casing.
- Push the Rast-5 plugs back into the correct
positions.
A
Mains connection 230 VAC/50 Hz
C
Programmable output A1
G
Flue gas damper connection
D
Programmable input E1 zero volt
E
2-wire eBUS connection, digital Wolf control
accessories
F
Outside temperature sensor
A C G D E F
.
230 V < 24 V
230 V < 24 V