26
3062347_0309
The eBUS address can only be displayed here. The setting is done as described
in "Conversion/eBUS address in cascade operation" and is only required in
cascade operation with several boilers.
eBUS address
Parameter HG10
HG10
1
Factory setting: 1
Setting range: 1 to 4
Gas type set according to the following table:
1 = Natural gas
0 = LPG
The modulating current for the gas combi valve is adjusted to fi t with the
relevant setting.
The conversion of the gas type can also be carried out through the selector or the
heating temperature selector (see control settings after gas type conversion).
Gas type
Parameter HG12
HG12
1
Factory setting: 1
Setting range: 0 to 1
Outside of the DHW switching times (in the control accessories) and in summer
mode, water can be heated to and kept at a certain temperature in the fl at-plate
heat exchanger.
10 °C = DHW quick start disabled
40-60 °C = DHW quick start enabled
DHW Quick Start
Parameter HG11
HG11
10
Factory setting: 10 K
Setting range: 40 to 60 K
Displaying / modifying control parameters
with Wolf control accessories
Each time the burner is shut down in heating mode, it will be blocked for the
duration of the burner cycle block.
The burner cycle block is reset by switching the ON / OFF switch OFF and ON
or by briefl y pressing the reset button.
Burner cycle block
Parameter HG09
HG09
7
Factory setting: 7 min
Setting range: 1 to 30 min
Summary of Contents for CGG-2-18
Page 64: ...64 3062347_0309 Notes ...