58
3062547_201802
The following balanced flues or standard flues with CE-0036-CPD-9169003 certification may be used (see also the balanced
flue system:
● Flue DN60
● Concentric balanced flue DN60/100
● Flexible flue DN60
● Flue DN80
● Concentric balanced flue DN 80/125
● Concentric balanced flue (on an external wall) DN 80/125
● Flexible flue DN 83
● Flue DN 110
● Flexible flue DN 110
● Concentric balanced flue DN 110/160
● DN 160 flue (for cascade operation)
The necessary type plates and certificates are included with the relevant WOLF accessories.
Please also observe the installation information supplied with the accessories.
Connection types
Boiler
Type
Appliance type
1), 2), 3)
Operating mode
Can be connected to
Room
unsealed
Room
sealed
Moisture-
resistant chimney
Balanced flue
chimney
Air/flue gas
routing
Certified
balanced flue
Moisture-
resistant flue
COB-
15/20/
29/40
B23, B33, C33x,
C43x, C53,
C53x, C63x,
C83x, C93x
Yes
Yes
B33, B23, C83x
C43x
C33x, C53x,
C93x
C63x
B23, C53x,
B33
1)
Mark "x" indicates that all components of the flue are surrounded by combustion air and meet higher requirements for gas tightness.
2)
For types B23 and B33, the combustion air is drawn from the installation room (open flue combustion equipment).
For type C, the combustion air is drawn through a sealed system from the outside (balanced flue combustion equipment)
36 Technical information
Provide ventilation for B23, B33, C53