Electrical Requirements
Required Electrical Supply
•
240 volts AC, 60 Hertz, 30 ampere fused electrical supply for 30” and 36” units.
•
240 volts AC, 60 Hertz, 50 ampere fused electrical supply for 48” and 60” units.
•
Separate circuit serving only this appliance.
•
Installation site must be equipped with a properly grounded receptacle.
Maximum Connected Load
•
5,200 Watts for 30” and 36” units.
•
10,000 Watts for 48” and 60” units.
Minimum Electrical Wire Size
30” and 36”
•
L1 and L2 - 12 AWG
•
Neutral - 16 AWG
•
Ground - 12 AWG
48” and 60”
•
L1 and L2 - 8 AWG
•
Neutral - 12 AWG
•
Ground - 10 AWG
The unit is designed with a terminal block on the rear of the range. The terminal block allows for 3-wire or 4-wire
installation. For a 4-wire installation, the ground strap from the unit to the terminal block must be cut. Two concen-
tric knockouts
(on the terminal block)
, are provided to allow a certified electrical contractor to wire the range directly
to a junction box.
The terminal block will also accept an appliance power cord. The power cord must be sized correctly for the units
voltage and amperage.
Please refer to state, municipal and local codes for the best means to connect the appliance to the electrical power
supply.
A SHOCK HAZARD COULD EXIST IF THE ELEC-
TRIC RECEPTACLE OR THE POWER CORD ARE
NOT PROPERLY GROUNDED AND POLARIZED.
The appliance may experience ignition problems if
not properly grounded and polarized.
Summary of Contents for DF304
Page 2: ......
Page 12: ...D Du ua al l F Fu ue el l R Ra an ng ge e General Information 1 10 ...
Page 62: ...4 22 Component Access Removal D Du ua al l F Fu ue el l R Ra an ng ge e ...
Page 77: ...Technical Data D Du ua al l F Fu ue el l R Ra an ng ge e 6 1 SECTION 6 TECHNICAL DATA ...
Page 81: ...Wiring Diagrams D Du ua al l F Fu ue el l R Ra an ng ge es s 7 1 WIRING DIAGRAMS SECTIO N 7 ...