M. CONSTANT SPARKING AT
GRIDDLE / FT
N. INTERMITTENT SPARKING
AT GRIDDLE / FT
O. POOR IGNITION AT
GRIDDLE
P.
NO IGNITION AT
GRIDDLE / FT
Q. CANNOT REGULATE
TEMPERATURE AT
GRIDDLE
Ground wire disconnected at outlet in wall
or power cord to unit terminal block
Ground wire on DSI board loose or defec-
tive
Defective solenoid assembly
Arc at cut or splice in electrode wire
Cracked or damaged electrode
Arc at cut or splice in electrode wire
Bad connection at the J1 connector on the
DSI board
Bad connection at the GND connector on
the DSI board to unit chassis
Defective DSI board
Cracked or damaged electrode
Electrode not positioned properly to
Infrared burner, not close enough to tile sur-
face
Partially plugged holes in the burner tile
Incorrect orifice size
Gas pressure
Blockages in mixer tube or orifice
Bent orifice bracket holder
Improper gas type
Defective electrode
No gas
Defective DSI board
Kinked or pinched capillary tube on the
thermostat
Thermostat bulb not installed properly
Defective thermostat
May have to call an electrician
Check ground wire. Replace if defective
Replace solenoid assembly
Replace electrode
Replace electrode
Check for break in insulation. Replace elec-
trode if defective
Perform DSI board troubleshooting procedures
located at end of section 6
Check GND wire connections. Ohm ground
wire. Replace if defective
Perform DSI board troubleshooting procedure
located at end of section 6
Replace electrode
Reposition electrode properly to Infrared burner.
Electrode should be clear of the screen and
1/8
”
above the tile
Clear as necessary with wire paper clip.
Replace burner if too many burner holes are
clogged.
Check orifice stamp number. Replace if incor-
rect
Check gas pressure with a manometer
Clear or clean as necessary
Straighten bracket holder so gas jet is aimed
straight down mixing tube or replace bracket
holder
Check for gas type and advise owner if improp-
er. May have to convert unit to LP/Natural gas
Ohm electrode with wire. If open replace elec-
trode
Check gas supply, make sure gas is turned on
at shut off valve on manifold and supply source.
Check gas pressure with a manometer
Perform DSI board troubleshooting procedures
located at end of section 6
Straighten capillary tube if possible. Replace
thermostat.
Install thermostat bulb properly
Replace thermostat
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
Problems Associated with the Griddle
Summary of Contents for DF304
Page 2: ......
Page 12: ...D Du ua al l F Fu ue el l R Ra an ng ge e General Information 1 10 ...
Page 62: ...4 22 Component Access Removal D Du ua al l F Fu ue el l R Ra an ng ge e ...
Page 77: ...Technical Data D Du ua al l F Fu ue el l R Ra an ng ge e 6 1 SECTION 6 TECHNICAL DATA ...
Page 81: ...Wiring Diagrams D Du ua al l F Fu ue el l R Ra an ng ge es s 7 1 WIRING DIAGRAMS SECTIO N 7 ...