background image

Planning Information

L Series Built-In Double Ovens

M O D E L S   D O 3 0 F   A N D   D O 3 0 U

Dimensions in parentheses are in
millimeters unless otherwise specified.

4

5" 

(127) 

E

28

1

/

2

"

(724) 

OPENING WIDTH 

4" 

(102) 

E

E

E

33" 

(838) 

RECOMMENDED CABINET WIDTH 

30"

min (762) 

 

49

5

/

8

"

(1260) 

OPENING 

HEIGHT 

24"

min (610) 

OPENING DEPTH 

 

67"

typical

(1702)

ELECTRICAL LOCATION 
WITHIN OPENING 
APPLIES ONLY TO
CABINETS DEEPER 
THAN 24" (610)

W A L L   I N S T A L L A T I O N

IMPORTANT NOTE: Unless you are using cabinets deeper
than 24" (610), it is recommended that the electrical supply
be placed in an adjacent cabinet within reach of the conduit.
Choose the location shown in the illustration that best suits
your installation.

Summary of Contents for DO30F

Page 1: ...l closes It s an attractive feature and will enable you to hide that control panel that many of us have labored to make functional and tried to make beautiful Inside the beauty design and functionality continue Brilliant halogen lights illuminate the beautiful blue interior As you open the oven door feel the smoothness of the door damper system Pull that bottom oven rack all the way out and notice...

Page 2: ...ired dehydrate accessory required and proof in each oven Rotating glass touch control panel Cobalt blue porcelain oven interiors Three removable racks six level rack guides and full extension bottom rack in each oven Large viewing triple pane windows Dual interior halogen lighting Hidden bake element and recessed broil element in each oven Temperature probe and receptacle in each oven Self clean d...

Page 3: ...Height 495 8 1260 Trim Overlaps 3 16 5 top 1 8 3 bottom 3 4 19 each side Electrical Supply Requirements 240 208 V AC 60 Hz 50 amp circuit Conduit 5 ft 1 5 m flexible 4 wire Electric Rating 8 9 kW at 240 V 6 7 kW at 208 V Total Amps 37 Shipping Weight 466 lbs 211 kg Specifications are subject to change without notice M O D E L O P T I O N S Framed Door Style Classic Stainless Steel DO30F S Unframed...

Page 4: ...H 30 min 762 495 8 1260 OPENING HEIGHT 24 min 610 OPENING DEPTH 67 typical 1702 ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 24 610 W A L L I N S T A L L A T I O N IMPORTANT NOTE Unless you are using cabinets deeper than 24 610 it is recommended that the electrical supply be placed in an adjacent cabinet within reach of the conduit Choose the location shown in the illust...

Page 5: ...ouble ovens require a separate grounded 4 wire 240 208 V AC 60 Hz 50 amp service with its own circuit breaker It is provided with a 5 1 5 m flexible 4 wire conduit for connection at the electrical supply IMPORTANT NOTE Unless you are using cabinets deeper than 24 610 it is recom mended that the electrical supply be placed in an adjacent cabinet within reach of the conduit Refer to the illustration...

Reviews: