background image

Troubleshooting

IMPORTANT NOTE:

If the dual fuel range does not operate

properly, follow these troubleshooting steps:

Verify that electrical power is being supplied to the

range.

Check electrical and gas supply connections to ensure

that the installation has been completed correctly.

Check that the gas supply shut-off valve is in the open

position.

Follow troubleshooting procedures outlined in the

Wolf dual fuel ranges use & care guide.

If the range still does not operate properly, contact a

Wolf authorized service center. Do not attempt to repair

the range yourself. Wolf is not responsible for service

required to correct a faulty installation.

Service Information

If service is necessary, maintain the quality built into your

dual fuel range by calling a Wolf authorized service center.

To obtain the name and number of a Wolf authorized

service center, check the contact & support section of our

website, wolfappliance.com or call Wolf customer service

at 800-332-9513.

When calling for service, you will need the model and

serial numbers of the dual fuel range. Both numbers are

listed on the product rating plate, located on the bottom of

the control panel assembly, at the far right, just above the

oven door. Refer to the illustration below.

Location of rating plate.

RATING PLATE

Service Information

19

wolfappliance.com/specs

The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein
may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.

Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc.
(collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.

Summary of Contents for DUAL FUEL RANGES

Page 1: ...INSTALLATION GUIDE Dual Fuel Ranges...

Page 2: ...ctions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Dual Fuel Ranges 3 Safety Instructions 4 Dual Fuel Range Specificat...

Page 3: ...a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Wolf dual fuel ranges are manufactured for use with natural...

Page 4: ...wall or floor where the range is to be installed must be sealed A ventilation hood is recommended for use with the Wolf dual fuel range In Massachusetts Installations and repairs must be performed by...

Page 5: ...SURFACE 60 1527 RANGE 477 8 1216 367 8 937 HEIGHT TO COOKING SURFACE 601 8 1527 407 8 1035 5 RISER 457 8 1165 10 RISER 557 8 1419 20 RISER 47 1194 261 8 664 25 635 241 8 613 271 2 699 91 4 235 291 2 7...

Page 6: ...olfappliance com Failure to locate the range without the proper clear ances will result in a fire hazard VENTILATION The dual fuel range must have an adequate supply of fresh air to assure proper comb...

Page 7: ...RANGES Power supply 240 208 V AC 60 Hz with 30 amp service Maximum connected load 5 2 kW Total amps 21 amps Supply wire minimum size L1 L2 and ground 12 AWG neutral 16 AWG 48 AND 60 DUAL FUEL RANGES P...

Page 8: ...it a certified 3 9 m long 1 2 or 3 4 ID flexible metal appliance connector is recom mended to connect the range to the gas supply line For LP gas piping or tubing size can be 1 2 minimum LP gas suppli...

Page 9: ...essure to the regulator should never exceed 14 34 9 mb WC 5 psi 3 5 kPa for natural and LP gas The minimum line pressure is 7 17 5 mb WC for natural gas and 11 27 4 mb WC for LP gas Gas Pressure Regul...

Page 10: ...ertop 36 914 minimum clearance from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to combustible rear wall abov...

Page 11: ...ertop 36 914 minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to co...

Page 12: ...minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to combustible rea...

Page 13: ...ertop 36 914 minimum clearance 44 1118 for charbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of range to co...

Page 14: ...ange must be level Use the adjustable front legs and the rear casters to level the range This range can tip Injury to persons could result Install the anti tip bracket supplied with the range ANTI TIP...

Page 15: ...moval may cause damage to the porcelain oven interior or the door s Door removal should be done by a qualified service technician or installer For removal a hinge pin supplied with the range must be i...

Page 16: ...onnect the red appliance wire to the red L2 power supply wire in the electrical box 5 Connect the ground appliance wire to the green ground house grounding wire in the electrical box Verify that power...

Page 17: ...to test for leaks Bubbles around connections will indicate a gas leak If a leak appears close the gas shut off valve and adjust connections Check for leaks again Clean off the detergent solution Dual...

Page 18: ...Wolf authorized service center IMPORTANT NOTE Initial lighting of the surface burners may take slightly longer as air in the system must be purged before gas can be supplied to the burner OVEN OPERATI...

Page 19: ...customer service at 800 332 9513 When calling for service you will need the model and serial numbers of the dual fuel range Both numbers are listed on the product rating plate located on the bottom of...

Page 20: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 332 9513 816980 REV A 8 2010...