Dual Fuel Range Specifications
7
wolfappliance.com/specs
WIRING DIAGRAM
The wiring diagram covering the control circuit is located
behind the control panel on top of the cavity insulation
retainer and under the control board.
Electrical Requirements
Locate the electrical supply flush with back wall and within
the shaded area shown in the illustration for your specific
model on the following pages.
30" AND 36" DUAL FUEL RANGES
•
Power supply: 240 / 208 V AC, 60 Hz with 30 amp
service.
•
Maximum connected load: 5.2 kW.
•
Total amps: 21 amps.
•
Supply wire minimum size: L1, L2 and ground—
12 AWG, neutral—16 AWG.
48" AND 60" DUAL FUEL RANGES
•
Power supply: 240 / 208 V AC, 60 Hz with 50 amp
service.
•
Maximum connected load: 10.2 kW.
•
Total amps: 42.5 amps.
•
Supply wire minimum size: L1 and L2—8 AWG,
ground—10 AWG, neutral—12 AWG.
IMPORTANT NOTE:
You must follow all National Electrical
Code regulations. In addition, be aware of local codes and
ordinances when installing your service.
IMPORTANT NOTE:
Performance may be compromised if
the electrical supply is less than 240 volts.