Internal Blowers
WIRING FOR INTERNAL BLOWER
1)
Remove the hood electrical box cover. Run Romex
®
wire from a 120 V AC, 15 amp circuit to the hood
installation location. Insert the Romex
®
wire into the
electrical box by running it through the wire clamp
previously installed. Tighten the wire clamp to secure
the wire. Refer to the illustration and chart below for
the location of wiring for your specific hood. Do not
remove the wire connector on the orange wire in the
hood electrical box.
2)
Using the wire connectors provided, connect black
wire to power supply black wire, white wire to power
supply white wire and green or bare wire from power
supply to green ground screw in the electrical box.
3)
Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
Blower Assemblies
Pro ventilation hoods are shipped without the blower
assembly. Internal, in-line and remote blowers are avail-
able through your authorized Wolf dealer. For local dealer
information, visit the find a showroom section of our
website, wolfappliance.com.
The blower will vary in size and is dictated by the cooking
surface, the volume of air that needs to be moved and the
length of the duct run. Refer to ventilation recommenda-
tions in the Wolf design guide.
IMPORTANT NOTE:
Use wire connectors or wire nuts
approved by UL or C/UL.
Pro Wall Chimney Hood Installation
13
wolfappliance.com/specs
A
1
1/2
"
(38)
2"
(51)
Location of hood wiring.
Location of Hood Wiring
WIDTH OF HOOD
A
36"
(914)
2"
(51)
42"
(1067)
3"
(76)
48"
(1219)
4"
(102)
54"
(1371)
4"
(102)
Before making electrical connections, make sure the
electrical power is turned off at the service panel.
To reduce the risk of fire and electric shock, install
this ventilation hood only with a blower manufactured
by Wolf.