S E RV I C E  

If service is necessary, maintain the quality
built into your gas range by calling a Wolf
authorized service center.

To obtain the name and number of a
Wolf authorized service center, check
the Locator section of our website,
wolfappliance.com or call Wolf Customer
Service at 800-332-9513.

When calling for service, you will need the
model and serial numbers of the gas range.
Both numbers are listed on the product
rating plate, located under the drip pan that
supports the cooking grates, on the left
inside wall of the range. Refer to the
illustration on page 3. The rating plate for
Model R482CF is located on the right inside
wall.

T R O U B L E

S H O O T I N G

IMPORTANT NOTE: If the gas range does not
operate properly, follow these troubleshooting
steps:

Verify that power is being supplied to the
range.

Check the gas supply and electrical
connections to ensure that the installation
has been completed correctly.

Check that gas valves are turned to the ON
position.

Check polarity of the electrical outlet should
nuisance clicking of igniters occur immedi-
ately after installation.

If the range still does not work, contact a
Wolf authorized service center. Do not
attempt to repair the range yourself. Wolf
is not responsible for service required to
correct a faulty installation.

Summary of Contents for R304LP

Page 1: ...INSTALLATION INSTRUCTIONS G A S R A N G E S...

Page 2: ...ould like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if yo...

Page 3: ...der the drip pan that supports the cooking grates on the left inside wall of the range Refer to the illustration below The rating plate for Model R482CF is located on the right inside wall W O L F GAS...

Page 4: ...trong draft areas such as windows doors and strong heating vents or fans Do not obstruct the flow of air The area in which you are installing this appliance must have an adequate supply of fresh air t...

Page 5: ...nd insulated homes A qualified HVAC contractor should be consulted A C C E S S O R I E S Optional acces sories are available through your Wolf dealer To obtain local dealer information visit the Locat...

Page 6: ...illustrations for your model on pages 7 10 for the exact rough opening dimensions WA L L I N S TA L L AT I O N S Minimum clearances to combustible surfaces A minimum clearance of 18 457 must be maint...

Page 7: ...in 457 TO COUNTERTOP 37 940 TO COOKING SURFACE 13 max 330 6 min 152 TO COMBUSTIBLE MATERIALS BOTH SIDES 30 762 OVERALL WIDTH 36 914 37 940 OVERALL HEIGHT TO COOKING SURFACE 21 2 64 241 2 622 251 4 641...

Page 8: ...LS BOTH SIDES 36 914 OVERALL WIDTH 36 914 37 940 OVERALL HEIGHT TO COOKING SURFACE 21 2 64 241 2 622 251 4 641 LEGS AND CASTERS ALLOW 1 25 HEIGHT ADJUSTMENT 433 8 1102 463 4 1187 WITH 10 RISER 563 4 1...

Page 9: ...13 max 330 6 min 152 TO COMBUSTIBLE MATERIALS BOTH SIDES 48 1219 OVERALL WIDTH 36 914 37 940 OVERALL HEIGHT TO COOKING SURFACE 21 2 64 241 2 622 251 4 641 LEGS AND CASTERS ALLOW 1 25 HEIGHT ADJUSTMENT...

Page 10: ...60 1524 OVERALL WIDTH 36 914 37 940 OVERALL HEIGHT TO COOKING SURFACE 21 2 64 241 2 622 251 4 641 LEGS AND CASTERS ALLOW 1 25 HEIGHT ADJUSTMENT 433 8 1102 463 4 1187 WITH 10 RISER 563 4 1441 WITH 20 R...

Page 11: ...WALL FLOOR 61 2 165mm MIN TO FLOOR SIDE PANEL ANTI TIP BRACKET REAR CHANNEL BRACE Anti tip bracket installation This range can tip Injury to persons could result Install the anti tip bracket packed w...

Page 12: ...ges are located on the outer edges of the unit On these units the left oven door will have the spring hinge on the left side and the right oven door will have the spring hinge on the right side Refer...

Page 13: ...ange The 3 76 front legs are adjusted by rotating the bottom hexagonal portion of the leg The rear casters can be adjusted by rotating the 25 16 59 nut on the caster The range legs and casters allow f...

Page 14: ...olumn 5 psi 3 5 kPa Failure to do so can result in explosion fire or death W O L F GAS RANGES Gas Supply Line To Appliance SHUT OFF VALVE Open Position Shut off valve I M P O RTA N T N OT E This insta...

Page 15: ...WC water column A natural gas pressure regulator is installed For Propane LP Gas Standard orifices are set for 10 25 mb WC water column A propane gas pressure regulator is installed Gas Supply Pressu...

Page 16: ...and ordinances when installing your service R E C O M M E N D E D G RO U N D M E T H O D IMPORTANT NOTE This appliance must be properly grounded to avoid shock hazard The range is equipped with a 3 pr...

Page 17: ...llation may cause damage to the porcelain interior of the oven or door s If the oven door s have been removed as described on page 12 follow these steps to reinstall 1 Hold the oven door on both sides...

Page 18: ...tinues until the electronic ignition senses a flame Be sure to place the burner parts on each burner base and install the burner grates before lighting To check operation of the surface burners push i...

Page 19: ...Customer Service at 800 332 9513 When calling for service you will need the model and serial numbers of the gas range Both numbers are listed on the product rating plate located under the drip pan th...

Page 20: ...8 0 7 5 8 2 R E V B 1 0 2 0 0 6 WOLF APPLIANCE COMPANY INC P O BOX 44848 MADISON WI 53744 800 332 9513 WOLFAPPLIANCE COM...

Reviews: