Planning Information

48"

(1219)

Gas Rangetops

M O D E L S   R T 4 8 8   /   R T 4 8 6 C   /   R T 4 8 6 G   /   R T 4 8 4 C G   /   R T 4 8 4 D G   /   R T 4 8 4 F   /   R T 4 8 2 C F

Dimensions in parentheses are in
millimeters unless otherwise specified.

5

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications

for overall dimensions, finished rough opening
dimensions and installation specifics.

IMPORTANT NOTE:

Caution must be used in

planning the proper installation of the Wolf gas
rangetop to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Please
follow the minimum clearances established in
the finished rough opening dimensions as
shown in the Installation illustration.

IMPORTANT NOTE:

In non-island applications,

a riser is required when installing a 48" (1219)
gas rangetop against a combustible surface.

It is recommended that you use a Wolf Pro

wall or island ventilation hood or hood liner
with the Wolf gas rangetop. Pro Ventilation
information can be found on our website,
wolfappliance.com. Also refer to the Wolf
Design Guide for Pro ventilation recommenda-
tions.

The Wolf gas rangetop requires a 110 /120 V

AC, 60 Hz electrical supply to operate the elec-
tronic ignition system. The 6' (1.8 m) power
supply cord provided with the rangetop is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
Locate electrical and gas supply within the
shaded area shown in the Installation illustra-
tion.

IMPORTANT NOTE:

A ground fault circuit

interrupter (GFCI) is not recommended and may
cause interruption of operation.

Wolf gas rangetops are designed to operate

on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP (propane) gas at 10"
(25 mb) WC pressure. The minimum line
pressure for natural gas is 7" (17.5 mb) WC and
11" (27.4 mb) WC for LP gas. The maximum gas
supply pressure to the regulator should never
exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).

Wolf recommends the use of a 

1

/

2

" (13) I.D.

commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 

3

/

4

" (19) minimum I.D. pipe. 

IMPORTANT NOTE:

A separate external gas

shut-off valve must be located near the
rangetop in an accessible location. 

The Wolf gas rangetop functions up to

6,000' (1828 m) in altitude without any adjust-
ment. Installations above 6,000' (1828 m) need
the high altitude kit. Contact your Wolf dealer
for details. To obtain local dealer information,
visit the Locator section of our website,
wolfappliance.com.

You must follow all National Electrical Code

and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.

Refer to the installation instructions

shipped with each Wolf product for detailed
specifications.

Summary of Contents for RT482CF

Page 1: ...om to customize your gas rangetop Let Wolf the corporate companion and kitchen soul mate of Sub Zero fuel your passion for cooking and kitchen design Model RT488 Model RT486C Model RT486G Model RT484CG Model RT484DG Model RT484F Model RT482CF The Wolf 48 1219 gas rangetop is available in natural or LP gas with your choice of several top configurations Model numbers indicate the rangetop features C...

Page 2: ...ual brass burners with automatic reignition at all settings 500 Btu hr 1 kW simmer to 16 000 Btu hr 4 7 kW high Porcelain coated cast iron top grates Large red control knobs with four position settings and chrome bezels optional black knobs available at no cost Stainless steel drip tray on ball bearing slides Certified by Star K to meet religious regulations CSA certified for US and Canada Two and...

Page 3: ... O D E L O P T I O N S Eight Burners RT488 Six Burners Charbroiler RT486C Six Burners Griddle RT486G Four Burners Charbroiler and Griddle RT484CG Four Burners Double Griddle RT484DG Four Burners French Top RT484F Two Burners Charbroiler and French Top RT482CF Natural gas model listed for LP gas add LP to the model number V E N T I L A T I O N O P T I O N S 48 1219 Pro wall hood or liner 54 1372 Pr...

Page 4: ...e Wolf Design Guide for additional specifications VENTILATION HOOD 14 356 16 406 LOCATION OF GAS AND ELECTRICAL SUPPLY CUT OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM TOP VIEW OF PLATFORM E G 16 406 3 76 BACK WALL 1 2 13 481 4 1226 FINISHED ROUGH OPENING WIDTH 3 4 19 PLATFORM 6 min 152 TO COMBUSTIBLE MATERIALS BOTH SIDES 30 min 762 TO 36 max 914 COUNTERTOP TO BOTTOM OF VENTILATION HOOD 30 mi...

Page 5: ... with a 3 prong grounded plug for protection against shock hazard The service should have its own 15 amp circuit breaker Locate electrical and gas supply within the shaded area shown in the Installation illustra tion IMPORTANT NOTE A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation Wolf gas rangetops are designed to operate on natural gas at 5 12 5 m...