Controller for charging pump
Insert the electronic tank temperature sensor of the heating control into the upper im-
mersion sleeve for the tank sensor of the heater and fasten with the sensor bracket.
For tanks with a sensor channel, push the sensor in vertically as far as it will go. Set
desired tank temperature at the tank temperature controller of the heating control.
(max. 60°C).
Weather-compensated heating control
(heating control with integrated tank
temperature controller and tank tem
-
perature sensor)
Electrical auxiliary heating system
E2 / E4.5 / E6
The rules and regulations of the VDE and the local energy supply companies must be
observed.
The connection must be performed by a licensed electrician.
Disconnect power before opening devices! Never touch live components - risk
of injury or even death!
Unscrew the lid of the electrical auxiliary heating system and connect to the mains 230
or 400 V~ according to the enclosed instructions. Connecting wire must be provided
on site.
Electrical auxiliary heating system 2 kW/230V~, 4.5 kW/400 V~, 6 kW/400 V~.
with integrated tank temperature controller and safety temperature limiter.
Screw electrical auxiliary heating system into the 1 ½" pipe coupling at the solar tank
and seal it.
Electrical auxiliary heating system
3062505_201507