background image

INSTALLATION GUIDE

Sealed Burner Rangetops

Summary of Contents for SRT484CG

Page 1: ...INSTALLATION GUIDE Sealed Burner Rangetops ...

Page 2: ... not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed Contents Wolf Sealed Burner Rangetops 3 Safety Instructions 4 Sealed Burner Rangetop Specifications 5 Sealed Burner Rangetop Installation 13 Service Information 15 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to d...

Page 3: ...y a properly sized circuit breaker or time delay fuse The proper voltage frequency and amperage ratings are listed on the product rating plate Wolf sealed burner rangetops are manufactured for use with natural gas or LP gas Check the product rating plate for the type of gas for your specific model If this appli ance does not correspond to your type of gas contact your authorized Wolf dealer Record...

Page 4: ...s in the vicinity of this or any other appliance All openings in the wall where the rangetop is to be installed must be sealed A ventilation hood is recommended for use with the Wolf sealed burner rangetop In Massachusetts Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the state province or region where this appliance...

Page 5: ...ons 297 8 759 81 2 216 TO COOKING SURFACE 357 8 911 81 2 216 TO COOKING SURFACE 48 1219 RANGETOP 477 8 1216 261 8 664 121 2 318 5 RISER 171 2 445 10 RISER 271 2 699 20 RISER 281 2 724 81 2 216 TO COOKING SURFACE 71 2 191 91 4 235 241 8 613 36 914 RANGETOP SIDE VIEW ALL RANGETOPS 30 762 RANGETOP ...

Page 6: ...s will result in a fire hazard VENTILATION The sealed burner rangetop must have an adequate supply of fresh air to assure proper combustion and venti lation The location of the rangetop should be away from strong draft areas such as windows doors and strong heating vents or fans Do not obstruct the flow of air Due to the high volume of ventilation air required a source of outside replacement air i...

Page 7: ...t breaker A ground fault circuit interrupter GFCI is not recommended and may cause interruption of operation The 6 1 8 m power cord is equipped with a 3 prong grounding plug for protection against shock hazard The power cord must be plugged into a mating 3 prong grounded outlet grounded to conform with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA and all...

Page 8: ...rmit a certified 3 9 m long 1 2 13 or 3 4 19 ID flexible metal connector is recommended to connect the rangetop to the gas supply line For LP gas piping or tubing size can be 1 2 13 minimum LP gas suppliers usually determine the size and materials used on the system The pipe coming out the back of the rangetop has 1 2 13 female threads Pipe joint compounds suitable for use with natural or LP gas s...

Page 9: ...s supply pressure to the regulator should never exceed 14 34 9 mb WC 5 psi 3 5 kPa for natural and LP gas The minimum line pressure is 7 17 5 mb WC for natural gas and 11 27 4 mb WC for LP gas Gas Pressure Regulator To control and maintain a uniform gas pressure in the gas manifold the unit must be used with a gas pressure regulator The burner orifices etc are sized for the gas pressure delivered ...

Page 10: ... to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of rangetop to combustible rear wall above countertop 6 152 TO COMBUSTIBLE 6 152 TO COMBUSTIBLE 18 457 min 36 914 FLOOR TO COUNTERTOP 16 406 PLATFORM TOP VIEW E G 16 406 4 102 BACK WALL GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM 13 330 max PLATFORM 71 2 191 OPENING HEIGHT...

Page 11: ...rbroiler from countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of rangetop to combustible rear wall above countertop 6 152 TO COMBUSTIBLE 6 152 TO COMBUSTIBLE 18 457 min 36 914 FLOOR TO COUNTERTOP 16 406 PLATFORM TOP VIEW E G 16 406 4 102 BACK WALL GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM 13 330 max PLATFORM...

Page 12: ...m countertop to combustible materials without ventilation hood NOTE For island installations 12 305 minimum clearance from back of rangetop to combustible rear wall above countertop 6 152 TO COMBUSTIBLE 6 152 TO COMBUSTIBLE 18 457 min 36 914 FLOOR TO COUNTERTOP PLATFORM 16 406 GAS AND ELECTRICAL THROUGH BOTTOM OF PLATFORM PLATFORM TOP VIEW E G 16 406 4 102 BACK WALL 13 330 max PLATFORM 71 2 191 OP...

Page 13: ...rs close the gas shut off valve and adjust connections Check for leaks again Clean off the detergent solution Never test for a gas leak with a match or other flame FLEXIBLE METAL CONNECTOR ELBOW ADAPTER ADAPTER SHUT OFF VALVE NIPPLE BOTTOM OF RANGETOP Gas supply line connection Before connecting the gas supply make sure all valves are in a closed position Install the Rangetop Prepare the finished ...

Page 14: ... flame should light within four seconds If the burners do not light properly turn control knobs to the OFF position Check that burner caps are in the proper position Make sure electricity is being supplied to the rangetop and that the gas shut off valve is in the open position Check operation again If the burners still do not light properly contact Wolf factory certified service IMPORTANT NOTE Ini...

Page 15: ...check the contact support section of our website wolfappliance com or call Wolf customer service at 800 222 7820 When calling for service you will need the model and serial numbers of the sealed burner rangetop Both numbers are listed on the product rating plate located on the bottom of the control panel assembly at the far right Refer to the illustration below Service Information 15 wolfappliance...

Page 16: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 816998 REV A 1 2011 ...

Reviews: