Planning Information
When installing against a combustible surface, a minimum
10"
(254)
riser is required for a 36" dual fuel range with
charbroiler or griddle and all 48" and 60" models. Follow all
minimum clearances to combustible surfaces shown in the
illustration on the following page.
A Wolf pro ventilation hood is recommended with the dual
fuel range. If the range is to be installed without ventilation,
a 36"
(914)
minimum clearance, 44"
(1118)
for charbroiler,
from countertop to combustible materials above the range is
required. Refer to page 120 for pro ventilation.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit, servicing only this appliance
is required.
Wolf dual fuel ranges have a terminal block that allows for a
3-wire or 4-wire installation.
ELECTRICAL REQUIREMENTS
SINGLE OVEN RANGE
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
30 amp dedicated circuit
Total Amps
21
DOUBLE OVEN RANGE
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
50 amp dedicated circuit
Total Amps
42.5
GAS SUPPLY
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided to
the range. If local codes permit, a certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal appliance connector is
recommended to connect the units
1
/
2
" NPT female inlet to
the gas supply line.
Wolf natural gas ranges will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas ranges will func-
tion up to 8,600'
(2621 m)
. If the installation exceeds these
elevations, contact an authorized Wolf dealer for a high
altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
WC
Supply Pressure
5"
(12.5 mb)
Min Line Pressure
7"
(17.5 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
LP GAS
WC
Supply Pressure
10"
(25 mb)
Min Line Pressure
11"
(27.4 mb)
Max Regulator Pressure
14"
(34.9 mb)
, .5 psi
(3.5 kPa)
WOLF DUAL FUEL RANGES
Summary of Contents for SRT484CG
Page 1: ...Wolf Design Guide ...
Page 14: ...14 Wolf Customer Care 800 222 7820 ...
Page 28: ...28 Wolf Customer Care 800 222 7820 ...
Page 34: ......
Page 46: ......
Page 52: ......
Page 74: ......
Page 84: ......
Page 90: ......
Page 100: ......
Page 108: ......
Page 114: ......
Page 120: ......
Page 134: ...WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM 800 222 7820 WDG 11 2014 ...