2
3065440_201704
WOLF GMBH / POSTFACH 1380 / D-84048 MAINBURG / TEL. +49.0. 87 51 74- 0 / FAX +49.0.87 51 74- 16 00 / www.WOLF.eu
restore factory settings after replace-
ment of the controller
Please follow the instructions
below:
SWP-200 / 260 / 260B
SP1
55
SP2
55
SP3
45
SP5
62
SP6
75
SP7
10
SP8
40
SP9
-7
SP10
-25
CA1
2
CA2
0
CA3
0
r0
7
r1
40
r2
70
r3
40
r4
56
r5
0
C0
5
C1
5
C2
5
C3
0
C10
1000
C11
120
C12
1
C13
20
C14
20
d1
1
d2
3
d3
8
d17
-2
d18
60
Switch to expert mode and setting the parameters:
• press button
and button
for 4 seconds: the display shows „
PA
“ (password)
• press button
• press button
or button
to set the value „-
19
“
• press button
• press button
and button
for 4 seconds: the display shows the first parame-
ter „SP1“
To select a parameter:
• presss button
or button
To change a parameter:
• press button
• press button
or button
to increase or reduce the value of the parameter
• press button
To quite:
• press button
and button
for 4 seconds or wait for 60 seconds
It‘s necessary to turn the unit off and on again to activate the changing
of the parameters!
GB
Display
button
UP
button
DOWN
button
ON/Stand-by
button
SET
The following parameters are preset in factory. Do not change!
P0
1
P1
1
P2
0
P4
2
P5
0
P6
0
P8
5
A0
0
A1
10
A2
0
A3
0
A4
90
A5
0
A6
120
A7
15
A11
2
H0
30
H1
60
H3
2
i0
2
i1
0
i2
0
i3
1
i4
0
i8
0
i9
240
HOn1
--:--
HOF1
--:--
HOn2
--:--
HOF2
--:--
LA
247
Lb
2
LP
2
E9
0
u9
1
Hd1
1
Hd2
1
Hd3
1
Hd4
1
Hd5
1
Hd6
2
Hd7
2