11
3062165_201508
Distribute all roof hooks supplied evenly over the width of the collector
array to spread the loads applied. For this, position the roof hooks as
near to the rafters as possible.
CAUTION
Fixing material
Top roof hooks
with fixing bracket
Bottom roof hooks
with fixing bracket
Mounting rail
Mounting rail joint
set (if required)
Screws, nuts,
grub screws,
wood screws in a
bag
Rafter
compensation set
with wood screws
for rafter mounting
(available as an
accessory)
Rooftop installation - General
The data is provided without consideration to the installation location or the
pipe connections.
Standard dimensions for
determining the width of the
collector array
Length of mounting rail Alu + for 1 collector mounted on end 1030 mm
Length of mounting rail Alu + for 2 collectors mounted on end 2160 mm
Length of mounting rail Alu + for 3 collectors mounted on end 3290 mm
Length of mounting rail joiner:
100 mm
Collector width:
1100 mm
Distance between installed collectors:
31 mm
Installation on end (portrait)
Length of mounting rail Alu + for 1 collector mounted across: 2030 mm
Length of mounting rail joiner:
100 mm
Collector width:
2100 mm
Distance between installed collectors:
31 mm
Installation across (landscape)
Number of F3-1 collectors
1
2
3
4
5
6
7
8
9
10
Collector array width [m]
1.1
2.23
3.36
4.49
5.62
6.75
7.89
9.02 10.15 11.28
Mounting rail length [m]
1.03
2.16
3.29
4.42
5.55
6.68
7.81
8.94 10.07 11.20
Number of F3-1Q / F3-Q collectors
1
2
3
4
5
6
7
8
9
10
Collector array width [m]
2.1
4.23
6.36
8.49 10.62 12.75 14.89 17.02 19.15 21.28
Mounting rail length [m]
2.03
4.16
6.29
8.42 10.55 12.68 14.81 16.94 19.07 21.20
>15°