20
3062165_201508
Roof integration - Interlocking tile
30-60°
1. After fitting the extension, centre the mounting rail so that a gap of less than
12 cm is created on both sides between the collector array and the finished
tiling. If this is not possible, use half tiles or cut tiles to size. Ensure that the
gap dimension remains <12 cm to ensure the roof cover is fully rainproof.
2. Drill a Ø 5 mm hole and secure the mounting rail with the hexagon head cap
wood screw 8 x 80 and the wooden spacers (batten thickness less 9 mm)
to the rafters.
3. Affix the flashing tape in accordance with the diagram. For this, peel back
the protective foil only in the area actually to be used for the mounting rail.
The flashing tape must protrude approx. 30 cm on the left and right over
the flashing tape bases. Secure several flashing tapes to each other with
an overlap of at least 5 cm. (Do not as yet affix the flashing tape to the tiles
as the collectors must still be secured to the mounting rail.)
8 x 80
Wooden spacer
(batten thickness less 9 mm)
Overlap > 5 cm
Mounting rail
Flashing tape
Installation of the lower mounting rail
Wooden spacer
(batten thickness
less 9 mm)
Summary of Contents for TopSon F3-1