25
3062165_201508
Roof integration - Slate roof
1. Pre-drill with Ø 5 mm bit and secure the mounting rail to the rafters with the 8 x 80 hexagonal screws (provided).
2. Affix the flashing tape, taking care to remove the protective foil only in the area to be affixed to the mounting rail.
The flashing tape must protrude to the left and right approx. 30 cm over the flashing tape bases. If several strips
of flashing tape are used these must be joined with an overlap of at least 5 cm. (Do not yet affix the flashing tape
to the roof tiles as the collectors have yet to be secured to the mounting rail.)
Installation and extension
of the lower mounting rail
Flashing tape
base, left
Flashing tape
base, right
Connecting rail
Mounting rail for
2 collectors (2.26 m)
Mounting rail for
1 add. collector (1.13 m)
2 x M8 x 16
coach bolts
4 x M8 x 16
coach bolts
8 x 80
Overlap > 5 cm
Mounting rail
Flashing tape
Construction
Top panel
Collector
Mounting rail
Flashing tape
Waterproof substrate
15-60°