background image

Planning Information

Wolf Ventilation Recommendations

Dimensions in parentheses are in
millimeters unless otherwise specified.

7

24

1/2

"

(622)

15

1/2

"

(394)

28

1/4

"

(718)

20

3/4

"

(527)

24

3/4

"

(629)

14"

(356)

4

3/4

"

(121)

10" 

(254)

Diameter

14

3/4

"

(375)

29

1/2

"

(749)

29

1/2

"

(749)

18" 

(457)

22"

(559)

10

1/8

"

(257)

7

1/4

"

(184)

10"

(254)

10" 

(254)

Diameter

Remote BLOWER-60REM and
BLOWER-90REM

14

3/4

"

(375)

29

1/2

"

(749)

29

1/2

"

(749)

21" 

(533)

25"

(635)

10

3/8

"

(264)

7

1/4

"

(184)

10"

(254)

10" 

(254)

Diameter

W O L F   B L O W E R   A S S E M B L I E S

A ventilation system must include a blower

assembly. With a few exceptions where internal

blowers are included, Wolf ventilation hoods and

downdrafts are shipped without the blower

assembly. An internal, in-line or remote blower

assembly must be selected to accommodate the

cooking appliance, CFM requirements and home-

owner preferences. Internal, in-line and remote

blower assemblies are available as sales acces-

sories through your Wolf dealer.

Wolf internal, in-line and remote blowers are for

use with Wolf cooktop hoods, downdraft

systems and Pro ventilation hoods and hood

liners.

IMPORTANT NOTE:

Use only a Wolf blower

with all Wolf ventilation products.

Internal blowers are mounted inside the hood

canopy or downdraft blower box. In-line blowers

are mounted in between the hood and the

exterior of the home. Remote blowers can be

mounted on the roof or in some cases, on an

exterior wall. Refer to the illustrations below for

dimensions of Wolf in-line and remote blowers.

Ventilation recommendation charts on the

following pages provide minimum CFM recom-

mendations according to the cooking appliance

and ventilation system used and blower options

for each specific ventilation hood or downdraft.

Remote BLOWER-120REM

Remote BLOWER-150REM

11

3

/

4

"

(298)

21

1

/

2

"

(546)

24

3

/

8

"

(619)

 18

1

/

2

"

 (470)

12

1

/

4

"

(311)

4

1

/

2

"

(114)

18"

(457)

22"

(559)

24

7/8

"

(632)

 12"

(305)

18"

(457)

8"

(203)

In-line BLOWER-60IL

In-line BLOWER-110IL

Dimensions may vary by ±

1

/

8

" (3).

Summary of Contents for W542718

Page 1: ... hoods are recommended for use with all Wolf cooking appliances For optimal perform ance a Pro 27 686 deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle Wolf Pro 27 686 deep wall hoods are available in the classic stainless steel finish Rail option hoods R come with a classic stainless steel decorative rail and stand offs Optional platinum or bras...

Page 2: ...nd hand finished craftsmanship Recessed easy access controls Infinite speed blower control Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed Halogen lighting with two settings Heat lamps bulbs not included Removable dishwasher safe restaurant grade stainless steel baffle filters Transition with backdraft damper included UL listed to US and C...

Page 3: ...p wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle Specifications are subject to change without notice B L O W E R O P T I O N S 1200 CFM Internal Blower 804702 1100 CFM In Line Blower 808332 900 CFM Remote Blower 801641 1200 CFM Remote Blower 801642 1500 CFM Remote Blower 804701 Refer to the Pro Ventilation Recommendations chart at the end of this s...

Page 4: ...Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications I N S T A L L A T I O N S P E C I F I C A T I O N S 54 1372 WIDTH OF HOOD NOTE Horizontal discharge is applicable on 24 610 deep wall hoods used with WBLOWER 120INT or any remote blower 27 686 deep wall hoods are vertical discharge only 30 TO 36 762 914 TO COUNTERTOP 30 TO 36 762 9...

Page 5: ...in line and remote blower assemblies are available Blower options also vary with the volume of air that needs to be moved and the length of the duct run Refer to the end of this section for Pro ventilation recommendations and blower options IMPORTANT NOTE Install this ventilation hood only with a Wolf blower Pro wall hoods require a separate grounded 110 120 V AC 60 Hz power supply The service sho...

Page 6: ...NOTE Install these ventilation hoods only with a Wolf blower Refer to the Pro ventilation charts at the end of this section for recommendations and blower options 30 TO 36 762 914 COUNTERTOP TO BOTTOM OF VENTILATION HOOD 18 457 HEIGHT OF HOOD WALL HOOD DUCTWORK INSTALLATION THROUGH ROOF 36 914 STANDARD FLOOR TO COUNTERTOP HEIGHT 27 686 DEPTH OF HOOD 10 ROUND DUCT SOFFIT OR CABINET OR DUCT COVER VE...

Page 7: ...mblies are available as sales acces sories through your Wolf dealer Wolf internal in line and remote blowers are for use with Wolf cooktop hoods downdraft systems and Pro ventilation hoods and hood liners IMPORTANT NOTE Use only a Wolf blower with all Wolf ventilation products Internal blowers are mounted inside the hood canopy or downdraft blower box In line blowers are mounted in between the hoo...

Page 8: ...ong duct runs P R O V E N T I L A T I O N B L O W E R O P T I O N S Pro 27 686 Deep Wall Hoods Blower Description Blower Number Wall Hood Models 600 CFM Internal WBLOWER 60INT 807614 W302718 W362718 W422718 900 CFM Internal WBLOWER 90INT 805086 W302718 W362718 W422718 1200 CFM Internal WBLOWER 120INT 804702 W482718 W542718 W602718 W662718 600 CFM In Line BLOWER 60IL 808331 W302718 1100 CFM In Line...

Reviews: