background image

Warming Drawer WWD30-2

Electronic Control Info.

3-4

#814750 - Revision A - January, 2011

SYSTEM MODES:

The control can be placed into several different operational modes which changes preset conditions inside the warm-
ing drawer.  Details as to what each mode does to the operation of the drawer can be found below.

POWER UP:

Power up is defined as the initial application of power to the appliance through the power cord; not to be confused
with switching the unit on/off with the “Power On/Off”  key.  During power up, all segments of the LCD will illuminate
for 5 seconds before the unit goes into off mode.

After entering unit off mode, display will show “PF” in the time display until user presses a key.  If unit was previously
in a warming mode prior to power loss, control will also emit a power failure chime every 30 seconds while displaying
“PF” until the “Power On/Off” is pressed.

NOTE

Pressing any key will clear “PF” error and unit will operate normally.

ON MODES:

ON Modes control behavior of electrical components of the appliance when it is “ON”.  Switching the unit on is
accomplished buy pressing the “Power On/Off”  key.  When ON, any back lighting will immediately activate “- - -” will
be displayed in the temperature display with the respective temperature scale (F or C) blinking.  (

See Figure 3-4

)

NOTE

If no other key is pressed within 20 seconds, unit will switch off.

NORMAL WARMING MODE:

Normal warming mode is the basic operating mode when power is turned on and any warming function is selected.
This will include heating by the element and circulation of air by use of the fan.

Mode Entry:

The unit can be placed into a normal warming mode by simply pressing the “Power On/Off”  key followed by either
“TEMP” up or down arrow keys, or any preset is pressed.  (

See Figure 3-4

)

NOTE

If no other key is pressed within 20 seconds, unit will switch off.

Operations:

Once unit is turned on and “TEMP” up or down arrow  is pressed, unit will initiate at 120°F and can be adjusted in
increments of 1°F.  If you press and hold either arrow, the display will increase by 1° each 1/2 second until the first 5°
increment is obtained then will increase by 5° per 1/2 seconds.  (

See Figure 3-5

)

NOTE

Temperature is adjustable from 80°F to 200°F (26.7°C to 93.3°)

Mode Exit:

Pressing “Power On/Off” key will terminate Normal Warming Mode and shut unit off.

NOTE

:

The mode will also exit by reaching ‘0:00,’ on the timer.  At this point, ‘0:00’ will begin flashing and the ele-

ments and fan will shut off.  The control will also yield three chimes every 30 seconds to denote unit has shut off.
After 5 minutes the timer will self power down if the “Power On/Off” key is not pressed. 

 

TIMER

PROOF

LOW

PRESETS

HIGH

MED

TEMP

POWER
ON/OFF

PROOF

F

TEMP

TEMP

TEMP

ON

TIMER

Figure 3-5.  Temperature Adjustment in Normal Warming Mode.

TIMER

PROOF

LOW

PRESETS

HIGH

MED

TEMP

POWER
ON/OFF

PROOF

F

TEMP

TEMP

TEMP

ON TIMER

Figure 3-4.  Power On Mode.

Summary of Contents for WWD30-2

Page 1: ...ontrol will open the element relay Once the control sees a thermistor temperature of 5ºF below set point the relay will close allowing element to cycle on Power Relay Board Circulation Fan Element Display Board Keypad Flex Cable Inner ceiling Network Cable Electronic Control Board Behind Front Panel Door Switch Bottom of Drawer Front Display Beeper CONTROL all low temp components Keypad Communicat...

Page 2: ... will be remain off The PROOF is on anytime PROOF mode is being used The ON indicator is on anytime control is calling for heat The exception is during Sabbath mode where the ON indicator stays on constantly NOTE TIMER is on anytime there is a timed warming event or if kitchen timer is being used NOTE TIMER is not an option in Sabbath mode POWER Key The POWER key is used to turn unit on and off Wh...

Page 3: ...nit will switch off NORMAL WARMING MODE Normal warming mode is the basic operating mode when power is turned on and any warming function is selected This will include heating by the element and circulation of air by use of the fan Mode Entry The unit can be placed into a normal warming mode by simply pressing the Power On Off key followed by either TEMP up or down arrow keys or any preset is press...

Page 4: ...lash when first entering mode Once mode is active the TIMER will no longer be illuminated If no time is set timer will automatically default to 4 00 hours This ensures a definitive stop time Operations When HIGH Preset key is depressed control will display 200F in temperature display For MED temperature display will read 160F and for LOW temperature display will read 120F In timer area of display ...

Page 5: ...nt and fan maintains drawer temperature to set point temperature Fan is on while element is on during warming mode as long as drawer switch returns a drawer closed value If element has cycled off fan will continue to circulate air inside drawer for a pre determined time before turning off Fan will then re energize when element is turned back on during a call for heat PREHEAT Preheat can be describ...

Page 6: ...first 5 second increment is obtained then will increase by 5 seconds per 1 2 second If TIMER up or down arrow key is depressed for longer than 30 seconds display will increase by 30 minute increments each 1 2 second until 5 00 Hours is reached then increase in one hour increments up to 24 00 hours NOTE Timer will count up in time with 1 minute as the minimum setting and going up to 24 00 hours min...

Page 7: ... drawer is open for longer than 1 minute and the unit calls for heat element will randomly turn on and off If in Sabbath mode but a second key press does not occur withing 10 seconds the unit will enter OFF mode Mode Exit A press of the Power On Off key will terminate Sabbath mode and shut off unit at any time TIMER PROOF LOW PRESETS HIGH MED TEMP POWER ON OFF PROOF F TEMP TEMP TEMP ON TIMER Figur...

Page 8: ...es must be made when unit is in OFF mode See Figure 3 20 for a quick reference to keystrokes to enter modes and features Temperature Display Preference Control can be switched between Fahrenheit or Celsius by pressing and holding both TEMP up and down arrow key for 5 seconds Use the TEMP Up or Down arrow key to change from F to C or C to F See Figure 3 12 NOTE Press Power On Off key to exit and sa...

Page 9: ...sed on drawer state at full illumination NOTE Left side of display will show On continuously and the right side of display will flash between bclt and Sab Continuous mode Off refers to backlight continuously off only in Sabbath mode Outside of Sabbath mode back light works as normal based on drawer state at full illumination NOTE Left side of display will show Off continuously and the right side o...

Page 10: ...l control information parameters such as total hours used See Figure 3 17 3 19 NOTES Using the opposite TIMER up or down arrow key will reverse your previous order To clear error codes logged press and hold TIMER up and down arrow keys for 5 seconds while in Field Service Mode See Troubleshooting Section 5 for list of error codes and meanings NOTE Once you have made it through all errors and infor...

Page 11: ...perature over 10 minutes of continuous call for heat Occurs only during preheat mode and the door is closed Door switch closed when the keypad is being operated or unit turned on Drawer temperature rises to 250ºF in any mode state Cable wires that activate element or fan relays on power board are not making connection Replace Control Board In FSM Field Service Mode view temper ature as view by the...

Page 12: ... Display Contrast Change Mode LED Back Lighting Change Mode TEMP ELE Func ON Relay closed Element on TEMP ELE Func OFF Relay Opens Element Off TEMP Fan Func ON Relay closed Fan turns on TEMP Fan Func OFF Relay Opens Fan turns Off TEMP Dor CLOS if Drawer Closed OPEn If Drawer Open key press TEMP DISPLAY TIMER DISPLAY ON INDICATOR POWER ON OFF PROOF MED POWER ON OFF 5 Seconds 5 Seconds POWER ON OFF ...

Reviews: