Technical Data 

 
Operating Voltage 

 

230 / 240V ~ 50 Hz alternating current. 

 
Power Consumption 

200 – 750 W (see Data page) 

 
Protection Class 

 

II              

 
Dime Weight  (see Data page) 
 
The dimensions given are for the actual glass sizes; the size of the frame is additional. 
With M 10 these are approx. + 5 mm in the width and height. 
With M 23 these are approx. + 55 mm in the width and height. 
With HB 30 these are approx. + 30 mm in the width and height. 
With Frameless models, the tolerance of only the glass is taken which is +/-  2 mm. 
 
Technical details of all current models are listed in the Data Page (see page 8) 
 
The units comply with the test requirements of the European Low Voltage specifications 2006/95/EG and the 
harmonised Product Standards EN 60335-1 and EN 60335-2-30 and are marked with a 
CE Conformity Label. 
 

Guarantee and Service 

 
The Heating Panels are guaranteed by Wolff & Meier for 2 years after the purchase date. If these Operating and 
Installation Instructions are followed and are correctly adhered too, we guarantee the free-of-charge 
replacement of the Heating Panel if the problem occurring is directly related to a manufacturing or material fault. 
If however the problem has been caused by incorrect installation or operation, the free-of-charge guarantee 
becomes null and void. 
 
Your personal rights regarding this guarantee are not diminished. 
 

Service Address: 

 

Isolierglaswerke 
Wolffe & Meier GmbH & Co KG 
Am Wingert 16 
35428 Langgöns 
Germany 
Telephone: 

0049 (0) 6403/9006-0 

Fax 

 

0049 (0) 6403/9006-15 

E-Mail   

infranomic@wolff-meier.de

 

 
 
Version 0.5 2009-05-20 Eng. 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for infraNOMIC

Page 1: ...infraNOMIC INFRARED HEATING PANELS Operating and Installation Instructions Installation Instructions only for Framed Panels Wolff Meier GmbH Co KG Glaswerke Am Wingert 16 35428 Langgöns Germany ...

Page 2: ... make sure that you use the heater exactly as per the following instructions the adherence to these instructions is a pre condition to the manufactures liability regarding any guarantee cases After completion please store these instructions in a safe place so that they can be used again if necessary and also can be given to another user if the panel changes hands Contents Thank you for your purcha...

Page 3: ...clamp or in any other way damage the connecting cable attached to the Panel If the attached connecting cable does appear to be damaged please refer to the manufacturer or his service department or a similarly qualified person to undertake any repair work Do not attempt to carry out any repairs changes or modifications to the Heating Panel Before any assembly or cleaning work is carried out disconn...

Page 4: ... A 1 x Accessory Set which includes 2 x Hanging Plates B 4 x Bolts M6 x 8 C 2 x Bolts M6 x 25 D 2 x Hooked Mounting Screws E 2 x Rawl plugs 8mm F 4 x Ring Screws M6 for Ceiling Mounting G 1 x Operating and Installation Handbook If you discover that any parts are missing or are damaged please contact the company where you purchased the product or contact our Service department The Ring Screws G are...

Page 5: ... is 1 7 m long With difficult walls it may be necessary to use special rawl plugs When the Hooked Mounting Screws are screwed into the wall it is important that they are screwed in right up to the flange Wall Installation The Hanging Plates B should be attached to the shorter side of the heating Panel for vertical Installation and on the longer side for a horizontal installation The plates are att...

Page 6: ... Bolts C and Hanging Plates B from the heater Screw the 4 Ring Screws G into the integrated nuts and move these as far as practically possible towards the corners of the frame in a uniform manner These can be then hand tightened Measure the distances between the Ring Screws both from the short and long sides of the frame and transfer these measurements onto the ceiling where the panel is to be ins...

Page 7: ...r consumption of the Heater The power consumption of your heater is included in the information on the nameplate of the heater to be found on the back of the panel Tips for correct use When the Heater is turned on at first it is possible that for a short while you may be aware of a distinct sweet smell This is not harmful to health and if present is caused by the vaporisation of silicon in contact...

Page 8: ...etails of all current models are listed in the Data Page see page 8 The units comply with the test requirements of the European Low Voltage specifications 2006 95 EG and the harmonised Product Standards EN 60335 1 and EN 60335 2 30 and are marked with a CE Conformity Label Guarantee and Service The Heating Panels are guaranteed by Wolff Meier for 2 years after the purchase date If these Operating ...

Page 9: ...0 mm 65 400 9 1 14 5 ca 7 kg ca 5 kg ca 8 kg ca 7 kg 900 x 600 mm 96 500 14 6 21 8 ca 10 kg ca 10 kg ca 11 kg ca 13 kg ca 8 kg 1100 x 600 mm 116 600 21 9 25 9 ca 11 kg ca 11 kg ca 13 kg ca 16 kg ca 10 kg 1200 x 600 mm 126 700 26 34 ca 12 kg ca 12 kg ca 13 kg ca 17 kg ca 11 kg Heating Panel Coloured Type GHE RAL M10 X M24 X HB30 X P RL X SL Power Size of Room to be heated Aluminium Frame 10 mm Alum...

Reviews: