Safety Requirements and Regulations
Electric  fences  shall  be  installed  and  operated  so  that  they  cause  no  electrical  hazard  to
persons,  animals  or  their  surroundings.

Electric  fence  constructions,  which  are  likely  to  lead  to  entanglement  of  animals  or
persons,  shall  be  avoided.

· 

An electric fence shall not be supplied from more than one energiser or from independent
fence circuits of the same energiser.

· 

The gap between two separate electric fences with different energisers shall be at least 2m.

· 

If this gap is to be closed, this should be affected by means of an electrically non conductive
material.

· 

Barbed or razor wire shall not be electrified by an energiser.

· 

Any  part  of  an  electric  fence  which  is  installed  along  a  public  path  or  highway  shall  be
identified  by  warning  signs  (p/no  33020)  securely  fastened  to  the  fence  posts  or  firmly
clamped  to  the  fence  wires  at  recommended  intervals  of  approximately  10  metres  to  50
metres,  but  not  exceeding  90  metres.    Warning  signs  should  be  at  least  100mm  x
200mm  with  a  yellow  background.  The  inscription  shall  be  black  and  read: TAKE  CARE  -
ELECTRIC  FENCE, it  should  be  indelible  and  inscribed  on  both  sides,  lettering  height  of
at  least  25mm.

· 

Except  for  low  output  battery  operated  energisers,  the  energiser  earth  electrode  shall
penetrate  the  ground  to  a  depth  of  at  least  1m.

· 

Connecting  leads  that  are  run  inside  buildings  shall  be  effectively  insulated  from  the  earth
structural  parts  of  the  building.  This  may  be  achieved  by  using  double  insulated  high
voltage  cable  (p/no  31640).  Connecting  leads  that  are  run  underground  shall  be  run  in  a
conduit  of  insulating  material.

· 

Care  shall  be  taken  to  avoid  damage  to  the  connecting  leads  due  to  the  effects  of  animal
hooves  or tractor  wheels  sinking  into  the  ground.

· 

Connecting leads shall not be installed in the same conduit as the mains supply wiring,
communication cables or data cables.

· 

Connecting  leads  and  electric  fence  wires  shall  not  cross  above  overhead  power  or
communication  lines.

· 

Crossings  with  overhead  cables  shall  be  avoided  wherever  possible.  If  such  a  crossing
cannot  be  avoided,  it  shall  be  made  underneath  the  power  line  and  as  nearly  as
possible  at  right  angles  to  it.

· 

If connecting leads and electric fences are installed near an overhead power line the
clearances shall be:
1. Power Line Voltage: Under 1000 volts - Clearance: 3 Metres
2. Power Line Voltage: 1000 - 33,000 volts - Clearance: 4 Metres
3. Power Line Voltage: Over 33,000 volts - Clearance: 8 Metres

· 

If  connecting  leads  and  electric  fence  wires  are  installed  near  an  overhead  power  line,
their  height  above  ground  shall  not  exceed  2m.  This  height  applies  either  side  of  the
orthogonal  projection  of  the  outermost  conductors  of  the  power  line  on  the  ground
surface,  for  a  distance  of  -  2m  for  power  lines  not  exceeding  1000V  -  15m  for  power
lines  exceeding  1000V.

· 

A distance of 10m shall be maintained between the energiser and any other earth system
such as the household supply system protective earth or the telecom system earth.

· 

A warning sign as described earlier, shall be fitted to every point where persons may gain
ready access to the conductors.

· 

Where an electric animal fence crosses a public pathway, a non-electrified gate shall be
incorporated in the electric fence at that point or a crossing by means of stiles shall be
provided.

· 

At any such crossing, the adjacent electrified wires shall carry warning signs as described
earlier.

Please retain instructions for future reference.