111
3.13 BACKUP AND RESTORE
User can use WoMaster’ Backup and Restore configuration to save and load configuration through the switch. There
are 3 modes for users to backup/restore the configuration file.
Web
mode: In this mode, the switch acts as the file server. Users can browse the target folder and then type the file
name to back-up the configuration. Browse the target folder and select existed configuration file to restore the
configuration back to the switch. This mode is only provided by Web UI while CLI is not supported.
TFTP Server
mode: In this mode, the switch acts as TFTP client. Before do so, make sure that TFTP server is ready.
Then please type the IP address of TFTP Server and Backup configuration file name. This mode can be used in both
CLI and Web UI.
The description of the columns is as below:
TERMS
DESCRIPTION
TFTP Server IP
User needs to key in the IP address of TFTP Server here.
File Name
Type the correct file name of the configuration file.
Configuration File (
.conf
)
The configuration file of the switch is a pure text file. User can open it by
word/txt read file. User can also modify the file, add/remove the
configuration settings, and then restore back to the switch.
Action
User can choose to Load or Save configuration
USB
mode: this mode has two functions, Load Setting from File and Save Setting to USB. Load Setting from File, make
sure that the USB has been plugged on and it has the
.conf
file which is the backup files. After plugged on the USB,
the USB port will directly read the USB and then the backup file would be shown up by clicking the arrow down. Then
click
restore
. At the Save Setting to USB part, all of the configuration settings would be saved to the USB, with
.conf