47
The description of the columns is as below:
TERMS
DESCRIPTION
IP address
PD’s IP-address that installed on the port.
Cycle time
User measured the PD system boots duration time.
*Most of PD system – IP camera will take at least 40~50 seconds.
Here, we suggest that user sets the cycle time to 90 seconds.
Delete
Delete PD’s IP-address that has been selected.
After finished configuring the settings, click on
Submit
to save the configuration.
3.3.5 PoE EVENT
In this section, user is allowed to configure the PoE Event, the value is Enable and Disable. When the status is
enabled PoE itself will detect the PD, then it will deliver the power when the PD is detected.