22
3.1.4 DATE AND TIME
3.1.4.1 DATE AND TIME SETTING
The WoMaster’ switch has a time calibration function based on information from an NTP server or user specified
time and date, allowing functions such as automatic warning emails to include a time and date stamp.
The description of the columns is as below:
TERMS
DESCRIPTION
Current Time
User can configure time by input it manually. User also can click the
Get Time from PC
to get PC’s time setting.
Time Zone
Choose the Time Zone section to adjust the time zone based on the
user area.
NTP
Enable NTP Client update
by checking this box. The system will send
request packet to acquire current time from the NTP server that
assigned.
*Make sure that the switch also has the internet connection.
1st Time Server & 2nd Time Server
Choose from NTP Server List, to adjust User system time.
Daylight Saving Time
Enable the Daylight Saving Function and the setting of function start
and end time or disable it.
Daylight Saving Start
&
Daylight
Saving End
Allows user to sets the Start and End time individually.
After finished configuring, click on
Submit
to activate the configuration.
NOTE
:
The WoMaster’ switch does not have a real-time clock. The user must update the Current
Time to set the initial time for the WoMaster’ switch after each reboot, especially when there is no
NTP server on the LAN or Internet connection.