background image

 

 

6

 

P

REPARATION FOR 

S

TARTING

 

1.

 

The working environment for the compressor should be clean, dry and ventilated. 

2.

 

Keep the use voltage within 

±5% of rated voltage.

 

3.

 

Keep the oil level within the red circle leveller. 

4.

 

The recommended compressor oil is SAE30 or L-DAB 100 in ambient temperatures over 
10°C and use SAE10 or L-DAB 68 for ambient temperatures below 10°C. 

5.

 

Open the outlet valve, set the knob of pressure switch in position ON. Let the compressor 
run 10 minutes with no load to ensure lubricating the moving parts before regular service. 

7

 

O

PERATION AND 

A

DJUSTMENT 

 

1.

 

The compressor is controlled by the pressure switch under normal working conditions. It 
automatically  stops  as  pressure  reaches  the  maximum  and  will  restart  as  pressure 
decreases to the minimum. The rated pressure has been set at the factory so please do 
not adjust it. As soon as the motor is switched off, the compressed air in the discharge 
pipe should be released through the release valve under the switch. This is the necessary 
condition for  restart otherwise  the  motor  will be  damaged.  The  rated  pressure  can  be 
adjusted by turning the adjusting bolt of the switch. Contact us first before considering 
adjusting the rated pressure. 

2.

 

The outlet pressure of compressed air can be adjusted by the regulating valve. 

3.

 

When the compressor is running and needs to be turned off. Only set the knob of 
pressure switch in position OFF.  

 

 

 

Summary of Contents for W3D1/24

Page 1: ...0 AIR COMPRESSOR OPERATION MANUAL PLEASE FAMILIARISE YOURSELF WITH THE OPERATION MANUAL FIRST BEFORE OPERATING THE AIR COMPRESSOR...

Page 2: ...mpressor Head 3 Using the Sight Glass built into the lower front area of the Compressor just behind the Regulator check the oil level It should be at the halfway mark on the Sight Glass for normal ope...

Page 3: ...Guidelines 3 Brief Description 4 General View and Main Components 5 Main Technical Parameters 6 Preparation for Starting 7 Operation and Adjustment 8 Cautions 9 Maintenance 10Troubles and Remedies 11...

Page 4: ...in paint spray guns paint pumps etc and cause an explosion If you are using these solvents use only stainless steel spray equipment This does not affect your air compressor but many affect the equipm...

Page 5: ...ng properly and to clear the valve of any possible obstructions 3 To provide proper ventilation for cooling the compressor must be kept a minimum of 31cm 12 inches from the nearest wall in a well vent...

Page 6: ...where compressed air is required 4 GENERAL VIEW AND MAIN COMPONENTS 1 Main Compressor 2 Pressure Switch 3 Outlet Valve 4 Regulating Valve 5 Pressure Gauge 6 Drain Cock 7 One way Valve 8 Wheel 9 Disch...

Page 7: ...d by the pressure switch under normal working conditions It automatically stops as pressure reaches the maximum and will restart as pressure decreases to the minimum The rated pressure has been set at...

Page 8: ...t work as the motor has stopped find the cause immediately so as not to damage the motor 9 Lubricating oil must be clean and the oil level should be kept in the red circle leveller 10 Disconnect the...

Page 9: ...A foreign body may have gotten into the compressor 3 Piston knocking the valve seat 4 Moving parts seriously worn 1 Check and retighten 2 Check and clean away any foreign materials 3 Replace it with...

Page 10: ...9 11 PARTS ILLUSTRATION...

Page 11: ...re switch 1 14 Connecting rod 1 42 Pressure gauge 1 15 Rubber gasket 1 43 Outlet valve 2 16 Screw M5x14 6 44 Switch bracket 1 17 Crank case cover 1 45 Connector nut 1 18 Oil leveller washer 1 46 Disch...

Page 12: ...11 Address 5 Lyn Parade PRESTONS NSW 2170 E mail sales mtmwarehouse com au Telephone 02 9607 4300...