Your WoodMaster Force 30 must be installed by a professional and should follow all local, state and federal
laws and regulations. Any use of an unapproved installation may result in a voided warranty.
It is recommended to have your installation approved by WoodMaster. The Owner/Operator is responsible
for operating the furnace in a manner that does not create a nuisance condition. WoodMaster requirements,
state and local laws may not be sufficient in all conditions to prevent nuisance conditions due to factors that
vary at each location. Please plan your system accordingly.
Location
Your Force 30 can only be installed indoors. Ensure that the floor that the furnace is to be placed is level and
able to support the weight of the furnace plus the additional weight of the fuel. Ensure the feet are in the bot
-
tom of the furnace. Adjust the feet so the furnace sits level and the feet are loaded evenly.
There should be ample room around your furnace to make loading and cleaning of your furnace easier.
This area should also be clear of any easily combustible materials. Minimum clearance requirements are
42 inches for the top, 18 inches for the sides, 24 inches for the back and 36 inches for the front of the burner
when installed, with more space recommended at the front of the furnace to allow for more space when
cleaning. Make sure to leave ample space on either side of the furnace for the hopper.
The room where the furnace is placed should allow ample venting to ensure proper air flow to the
burner. A minimum vent size of 31 square inches recommended.
Below are the dimensions for the WoodMaster Force 30 without the burner installed. The burner will extend
approximately 16 inches from the mounting flange on the furnace. These dimensions are approximate. All
dimensions are in inches.