12
Mini Boiler Owners Manual
2015
Installation
Renovator Pellet Burner Installation
Install the mounting bracket to the boiler with the supplied
hardware. The holes on the frame are slotted to allow adjust
-
ments for proper alignment. Use fiberglass rope or similar
material to create a gasket between the boiler mounting
plate and the burner mounting bracket (a gasket may have
already been installed at the factory). Leave the bolts loose
to allow for adjusting when installing the burner. There is
a set screw on the ring of the bracket to lock the burner in
position. The set screw can be positioned on the top or on
either side.
Remove the red cover from the burner. Insert the burner into
the bracket. Do not install the burner to the maximum depth.
Leave a 1.5 inch gap between the mounting bracket and the
body of the Renovator. Tighten the four mounting bolts, then
make sure the burner is level, and tighten the set screw, be
-
ing careful not to over tighten.
Attach the tipping chute to the burner in the desired position
with the supplied thumb screws. The tipping chute can be
installed in multiple directions to allow for the pellet hopper
to be placed on either side of the boiler.