14
Mini Boiler Owners Manual
2015
Installation
Place the cover over the burner and secure it in place using
the four thumb screws provided.
Connect the wires to the burner. The Renovator Pellet Burn
-
ers have very simple connections that allow for easier re
-
moval for cleaning and maintenance.
A. Power Switch
B. Fuse
C. Power lead in
D. To feed auger
E. To Temperature Sensor
The protective cover on the burner cannot be removed with
-
out disconnecting these cables.
Install the probe in a well on the supply line next to the
boiler. Make sure the probe set screw contacts the metal of
the probe. DO NOT clamp the probe by the wire, this will
damage the probe. Contact paste can be used to increase the
accuracy of the probe.