The error “FUEL FAULT” can be displayed for multiple
issues:
1. Make sure there are pellets in the pellet hopper.
2. Make sure that the auger drive motor is working by
connecting the power cord of the burner and the
power cord of the auger.
3. If the pellet hopper is empty it is best to fill and
run the auger until pellets come again manually.
Let the auger run for approx. 10 -15 min to get an
even dosage.
4. Make sure the pellets in the pellet hopper are
not cavatating. If this is occurring, clean the pellet
hopper.
If the problem persists, contact your dealer or Northwest
Manufacturing, Inc. See the trouble shooting section for
further assistance.
11.
Error on the ignition element. This may be caused by an
incorrect start dose, a dirty burner or a failed igniter. Turn off
the burner and restart. Check to make sure you have the cor
-
rect start dose settings, or check the connection for the feed
auger. If the burner starts, no further action is needed. If not
see the troubleshooting section for further assistance. If the
problem persists or if the igniter is bad, contact your dealer
or Northwest Manufacturing, Inc.
Menu/Ok
FUEL FAULT
V22
1
2
3
4
Menu/Ok
IGNITION FAULT
V22
1
2
3
4
Operation
13. Shutting the Burner Off
When shutting off the burner, either for maintenance or for the season, the burner must be allowed to enter
and complete its shutdown process. Failure to allow the burner to shut down properly can result in damage to
the burner, especially if done repeatedly. It will also greatly reduce the burners efficiency. If the burner is idle
and the combustion fan is off, the burner can be switched off.
If the burner is running, the STOP set point on the operation temp screen should be adjusted so that it is lower
than the current boiler temperature. This will initiate the burners shut down process. Once the burner has air
cleaned and the combustion fan has turned off, the burner can be switched off. This process will take approxi
-
mately five minutes.