26
Mini Boiler Owners Manual
2015
Removal and Cleaning of the Burner (Monthly)
Disconnect the cables on the side of the burner.
Remove the four thumb screws that hold the cover on
the burner. Remove the cover.
Note: You should clean the boiler on an “as needed” basis, typically once a week. Not all wood pellets burn
the same, some may require you to clean the boiler more frequently. Your warranty does not cover ash cor-
rosion. The boiler must be completely cleaned of ash and creosote at least twice a year, including at the end
of the heating season. Neglecting to clean your boiler or cover the chimney when not in use, will void the
warranty.
WARNING: Before performing any of the following tasks, ensure that the power is disconnected from the
boiler and the burner, and that all components of the system have had ample time to cool.
Maintenance