Disconnect the red air line from the air compressor by
pushing in the blue collar on the fitting, while pulling
out on the hose.
Disconnect the white wire for the igniter, and remove
the black igniter wire from the relay on the side of the
fan. Disconnect the wires by pulling on the connectors.
Pulling on the wires will damage the connectors.
The burner can be removed in two different ways.
The first example removes the entire burner from the
furnace and should be done yearly for a full inspection
and cleaning. The second way leave the burner tube
installed and allow for easier access to the burn pot for
routine cleaning.
Maintenance
To completely remove the burner:
Remove the set screw from the mounting flange.