4
Mini Boiler Owners Manual
2015
• Read and follow these directions carefully. Retain this manual for as long as you own your boiler.
• All installation and operations must follow STATE and LOCAL CODES for wiring, and firing of this
unit. These CODES may differ from this manual. Installation must be performed by a qualified installer.
• Follow the manual carefully. Follow the recommended cleaning and maintenance.
• The WoodMaster Mini 30 is designed to be operated in a pressurized system. Make sure all necessary
safety components are installed and functioning properly.
• Freeze protection must be guaranteed in all water-bearing parts in the event of extensive idle
periods of the system. Note: Your WoodMaster Mini 30 is not intended to be your only heat source.
• Boiler water treatment must be used to ensure proper water quality.
• The chimney height may need to be adjusted depending on the installation and local codes. Do not connect
this unit to a chimney flue serving another appliance. Follow all state/local codes.
• Never open the ash door or top door during operation!
• Never operate any part of the system with covers, shields or panels removed.
• Anyone who is not familiar with and/or has not been trained to operate the boiler may not
operate the system. Only responsible adults should operate your boiler. If the boiler is not fired
properly damage could result and the warranty may be voided.
• Never allow children to play near or tamper with the burner, fuels/fuel tank or any other part of the system.
• Always keep the area around, and in front of the system clean and free from combustible materials.
• Keep animals away from the system.
• The operation may not be continued or restarted in the event of visible damages (for example,
thermal distortion, traces of smoke or fire, mechanical damages, etc.). Any damages must be repaired.
In the event of any doubts, please contact your authorized WoodMaster dealer.
• The system must not be exposed to external mechanical stress (for example, as storage, climbing
support, brace, or similar). This also applies for single parts (doors, covers, etc.).
• Only touch the PLC during the operation. Temperatures at other points (for example, chimney, ash
door, water lines…) can be very high.
• The WoodMaster Mini 30 must be operated exclusively according to the guidelines for planning,
assembly, regulations, statutes and product related instructions. The manufacturer is not liable for
damages and their results, if they occurred due to improper assembly, operation, application and also
inadequate maintenance and cleaning.
• Ensure that the burner is inserted to the proper depth of the boiler. Check this each time the
burner is removed for cleaning or servicing.
• After installation, the exhaust must be tested with an O2 sensor by your dealer for flue gas analysis.
• Disconnect all electrical power to the boiler before performing any service, except when servicing the
burner. There is a circuit breaker on the electrical box of the boiler that will shut off power to the burner,
but will leave power to your pump, light and outlet.
• The water pump must run continuously whenever the WoodMaster Boiler is being used.
Safety