8
Mini Boiler Owners Manual
2015
Installation
Your WoodMaster Mini Boiler must be installed by a professional and should follow all local, state and fed
-
eral laws and regulations. Any use of an unapproved installation may result in a voided warranty.
It is recommended to have your installation approved by WoodMaster. The Owner/Operator is responsible
for operating the boiler in a manner that does not create a nuisance condition. WoodMaster requirements,
state and local laws may not be sufficient in all conditions to prevent nuisance conditions due to factors that
vary at each location. Please plan your system accordingly.
Location
Your Mini Boiler can only be installed indoors. The Boiler may be installed inside the building that it
serves or in an out building. Your Mini Boiler must have protection against freezing.
Ensure that the floor that the boiler is to be placed is level and able to support the weight of the boiler
plus the additional weight of the water and fuel.
There should be ample room around your boiler to make loading and cleaning your boiler easier.
This area should also be clear of any easily combustible materials. Minimum clearance requirements are
42 inches for the top, 18 inches for the sides, 24 inches for the back and 36 inches for the front of the burner
when installed, with more space recommended at the front of the boiler to allow for more space when clean
-
ing the boiler. Make sure to leave ample space on either side of the boiler for the hopper.
The room where the boiler is placed should allow ample venting to ensure proper air flow to the
boiler. A minimum vent size of 31 square inches recommended.
Ensure the feet are in the bottom of the boiler. adjust the feet so the boiler sits level and the feet are
loaded evenly.
Below are the dimensions for the WoodMaster Mini Boiler without the burner installed. The burner will extend
approximately 16.25 inches from the mounting flange on the boiler. These dimensions are approximate.
33
.3
70
25
.3
00
26.500
23.971
37
.8
21
AD
JU
S
TA
B
LE
LE
G
S
W
IL
L
AL
LO
W
AP
X
2"
M
O
R
E
21
.5
63
33
.2
21
11
.5
33
17
.1
58
(4) 1
1
2
" COUPLING
22.235
6
20.250
Front
Top
Sides