MAINTENANCE
Safety Devices Inspection
MAINTENANCE
1597doc030112
6-11
6
6.11 Safety Devices Inspection
MP100E5S Moulder – Safety Devices Inspection
Safety devices on the machine which must be checked before every shift:
E-STOP button and its circuit inspection
Safety handle and its circuit inspection
1
Cutter cover safety switch and its circuit inspection.
1. E-STOP button and its circuit inspection
Turn the key switch to the “M” position;
1
Press and hold the safety handle;
1
The START button should illuminate green;
Press the START button to start the motor. The motor should start.
Press the E-STOP button located on the control box. The motor should be stopped. Pressing
the START button should not start the motor until the E-STOP button is released and the
START button is pressed.
1.
It doesn’t concern US version.
WMM028B
Switch,
Emergency
Stop
Switch, Motor
Start
Safety
Handle
1
Key Switch
1